background image

PAGE 3

The control valve uses no traditional fasteners (e.g. screws); instead clips, threaded caps and nuts and snap type latches 

are used. Caps and nuts only need to be firmly hand tightened because radial seals are used. Tools required to service 

the valve include one small blade screw driver, one large blade screw driver, pliers and a pair of hands. A plastic wrench 

is available which eliminates the need for screwdrivers and pliers. Disassembly for servicing takes much less time than 

comparable products currently on the market. Control valve installation is made easy because the distributor tube can 

be cut ½” above to ½” below the top of tank thread. The distributor tube is held in place by an o-ring seal and the control 

valve also has a bayonet lock feature for upper distributor baskets.

The AC adapter comes with a 15 foot power cord and is designed for use with the control valve. The AC adapter is for dry 

location use only. The control valve remembers all settings until the battery power is depleted if the power goes out. After 

the battery power is depleted, the only item that needs to be reset is the time of day; other values are permanently stored 

in the nonvolatile memory. The control valve battery is not rechargeable but is replaceable.

INSTALLATION

Allow one foot of clearance to service the valve.

The valve will withstand transportation and storage temperatures of -13 ˚F (-25 ˚C) to 131 ˚F (55 ˚C) and for short periods 

up to 158 ˚F (70 ˚C).  If valve has been exposed to freezing conditions let valve warm up to room temperature before 

running water through it.  The valve has been packaged to prevent damage from the effects of normal humidity, vibration 

and shock.
Place softener in desired location close to water supply inlet, after pressure tank, and near a source for waste water, 

(utility sink, floor drain or sewer line). A 115/120V, 60 Hz uninterrupted outlet is required. Keep softener far enough away 

from walls and other obstructions to allow enough room for servicing the unit. All sillcocks and similar fixtures that will 

use untreated water must have their pipes connected to the hard water side of the softener. The bypass valve should be 

installed so that water will be available if it should be necessary to shut off the pressure in order to service the softener.

The cabinet tank or mineral tank must be reasonably level and solidly in place. Prior to beginning work to the system, 

make sure that water pressure is shut off at the incoming water supply and that several water spigots are open to provide 

sufficient venting for drainage of that system.
Arrows are molded into the control valve to show the direction of the flow.

BYPASS VALVE: 

The bypass valve easily connects to the control valve body using nuts that only require hand tightening. 

Install with red knobs in the upward position. Press end of bypass valve with o-rings into valve. Hand tighten nuts. Place 

into 

BYPASS OPERATION (figure 1 page 3).

Avoid getting primer and solvent cement on any part of the o-rings or split rings, bypass valve or control valve. DO NOT 

use pipe dope or any other sealant on threads. Teflon tape is not necessary on the caps because of o-ring seals. Do not 

use Vaseline or other unacceptable lubricants on o-rings. A silicone lubricant may be used on black o-rings.

DRAIN LINE: 

The 3/4” drain line elbow accommodates 5/8” poly tube or 3/4” NPT drain line connections. The nut and 

poly tube insert for the 3/4” drain line elbow is designed for use with flexible poly tube only. The drain line elbow can be 

rotated so the outlet can be oriented toward the nearest drain

Click to buy NOW!

PD

F-XCHANGE

w

ww

.docu-track.c

om

Click to buy NOW!

PD

F-XCHANGE

w

ww

.docu-track.c

om

FIGURE 1

Содержание X FACTOR GOLD LINE LER

Страница 1: ...r This unit is designed to give you many years of trouble free service When installed in accordance with the following instructions and if given reasonable care clear soft water will be the result For...

Страница 2: ...ne prior to connecting the drain line flow control fitting Leave at least 6 between the drain line control fitting and solder joints when soldering pipes that are connected on the drain line control f...

Страница 3: ...er supply inlet after pressure tank and near a source for waste water utility sink floor drain or sewer line A 115 120V 60 Hz uninterrupted outlet is required Keep softener far enough away from walls...

Страница 4: ...of the overflow Do not connect the tubing to the drain line on the control valve Do not run tubing above overflow height at any point PROGRAMMING THE CONTROL VALVE Note A quick reference card is stor...

Страница 5: ...Set the amount of hardness in grains of hardness as calcium carbonate per gallon using the or buttons The default is 20 with value ranges from 1 to 150 in 1 grain increments Note The grains per gallon...

Страница 6: ...g steadily to drain without the presence of air momentarily press REGEN again Display will read RINSE Open the outlet valve of the softener or if using optional bypass place to NORMAL OPERATION MODE f...

Страница 7: ...is required The bypass consists of two interchangeable plug valves that are operated independently by red arrow shaped handles The handles identify the flow direction of the water The plug valves ena...

Страница 8: ...reinstall the PC board position the lower edge of the PC board so that the holes in the PC board line up with the plastic pins Push the top of the PC board towards the valve until it snaps under the...

Страница 9: ...atent 6402944 is a one piece design which allows the stack to be removed using your fingers The exterior of the stack is sealed against the body bore with self lubricating EPDM o rings while the inter...

Страница 10: ...l flow control assembly is installed in an easy to access refill elbow located on top of the control valve The refill flow control assembly is attached to the control valve with a locking clip The loc...

Страница 11: ...y E White 5 1 V3010 1F Injector Assy F Blue 5 1 V3010 1G Injector Assy G Yellow Not Shown V3170 O Ring 011 Not Shown V3171 O Ring 013 Injector plug and injector each contain one 011 and one 013 O Ring...

Страница 12: ...lbow Locking Clip 1 2 PKP10TS8 BULK Polytube insert 5 8 Option 3 V3192 WS1 Nut Drain Elbow Option 4 V3158 01 WS1 Drain Elbow Male 1 5 V3163 O ring 019 1 6 V3159 01 WS1 DLFC Retainer ASY 1 7 V3162 007...

Страница 13: ...Description 1 2 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 3 2 V3105 O Ring 215 4 2 V3149 1 PVC Male NPT Elbow Item No Qty Part No Description 1 1 H4600 3 8 Safety Brine Valve 2 2 10151 Pin 3 1 H4...

Страница 14: ...jack black wire and plug back in to reset control valve e Motor not inserted fully to engage pinion motor wires broken or disconnected motor failure e Check motor and wiring Replace motor if necessar...

Отзывы: