A metering pump will slowly supply the
pricise amount of fuel for your heat-
er model. This minimizes the need for
flame adjustments and allows for pump-
ing over longer distances (up to 100 ft.),
when necessary.
Section 5 - Fuel Supply Tank Installation
Metering Pump Installation
3/8” Soft Copper Tube
to Burner
3/8” Soft Copper Tube
Return to Tank
Metering Pump
Assembly
Vacuum Gauge
P/N 8398
Primary Strainer
P/N 9807
1/2” Pickup Tube
Check Valve
P/N 8662
Suction Line
Strainer
P/N 8748
Drain Valve
FRONT VIEW
SIDE VIEW
Bottom of strainer must be 6”
from the bottom of the tank
TOP VIEW
Tank Gauge Port
Fill Port
Emergency
Vent
Primary Vent
Fuel Pickup
Fuel Return