Section 2 - Systems & Controls
Electric Air-Solenoid Valve
The electric air-solenoid valve is controlled by the oil primary control. It acts as a shut-off
valve, (it’s open during operation, and closed when the burner is off
). The electric air
-solenoid valve is located inside the burner’s electrical box.
Air Operated Fuel Valve
The air-operated fuel valve controls fuel flow out of the nozzle. When the electric air-
solenoid valve opens and air pressure pushes on the fuel valve diaphragm, the plunger
moves off the nozzle seat allowing fuel to enter the nozzle. The air-operated fuel valve is
located on the back of the air preheater.
Air/Oil Preheater
The air/oil preheater is an assembly that preheats the atomizing air and fuel to a prede-
termined temperature to properly combust used oil. The air/oil preheater is located in the
burner.
Snap Disc
The snap disc accurately controls the temperature of the air/oil pre-heater assembly with
two resistance type cartridge-heating elements. The snap disc is mounted on the oil pre-
heater inside the burner.
Nozzle
The nozzle uses air pressure to help deliver fuel through its small orifice, and to atomize the
fuel for proper combustion. The nozzle is located on the end of the air pre-heater opposite
the fuel valve. Replace the nozzle annually, as they are prone to wear by contaminants in
waste oil.
Fuel Bypass Regulator (This is not used with the Optional metering pump)
The fuel bypass regulator controls the pressure of the fuel to the nozzle. The fuel bypass
regulator is located in the line between the outlet side of the pump and the burner.
Fuel Supply Pump
The fuel-supply pump delivers fuel from your oil storage tank to the burner. The fuel supply
pump should be located as close to the fuel supply tank as possible. The fuel supply pump
must be mounted with the motor shaft oriented horizontally.
Optional Metering Pump Assembly
The metering pump delivers fuel from your oil storage tank to the burner. It also controls
the volume of fuel, and no regulator is required. The metering pump should be mounted
with the motor shaft oriented horizontally.