background image

www.lamtec.de

Sensors and Systems for Combustion Engineering

Quick Reference for Endusers

ETAMATIC V

ETAMATIC V S

Содержание ETAMATIC V

Страница 1: ...www lamtec de Sensors and Systems for Combustion Engineering Quick Reference for Endusers ETAMATIC V ETAMATIC V S...

Страница 2: ......

Страница 3: ...to switch the Display 12 4 8 Operation and Display of the O2 Trim 13 4 9 Calling up O2 Trim Text Messages 13 4 10 Displaying the Running Time Meter 13 4 11 Displaying Checksums and Safety Times 14 5...

Страница 4: ...regulations DIN EN 298 2012 11 DIN EN 1643 2014 09 DIN EN 13611 2011 12 DIN EN 60730 2 5 2015 10 DIN EN 60730 1 2012 10 2014 35 EU Low Voltage Directive 2014 30 EU EMC Directive 2014 68 EU Pressure E...

Страница 5: ...ility of imminent danger If it is not avoided it may result in death or very serious injury The plant including its surroundings could be damaged CAUTION This draws the user s attention to the possibi...

Страница 6: ...es of possible actuators Combustion air valve Combustion air blower ETAMATIC VS only Fuel air valve Recirculation valve Up to 20 points usual 11 can be programmed per channel The Display is relative b...

Страница 7: ...on high firing rate The integral firing rate controller is built as a PID controller with special functions for combus tion engineering You may use it as a set value controller or controlled by atmosp...

Страница 8: ...ted by the 9 p Sub D plug with the ETAMATIC V Use for it the provided lead with the type no 663R0430 The data communication runs via the LAMTEC SYSTEM BUS Alternatively the possibility exists to attac...

Страница 9: ...minals for burner firing rate controller and actual value on the relay module type 660R0027 The flue gas damper remains open or the flue gas fan re mains at the highest speed The external burner seque...

Страница 10: ...meters Status Firing rate rating Setpoint Actual value feedback Setpoint feedback 2 Dig ital inputs Display change Compound O2 Flame inten sity UEAN Monitoring processor display 1 only if activated in...

Страница 11: ...d in the parameter section only available with ETAMATIC V ETAMATIC V S the option Integrated Flame Monitor Customer Interface Using the Keys reset firing rate fault history up firing rate fault histor...

Страница 12: ...output of the running time counter and the current time to de termine at which time the fault occurred Red fault LED is on Press key 17 to get STATUS display fault code Press key ENTER Plain text mess...

Страница 13: ...he display hides the O2 history automatically after 5 sec O2 trim faults which last for more than 30 sec are stored They are only stored in the EEPROM once the fault is cleared up or the ETAMATIC V le...

Страница 14: ...egular operation or Base firing rate operation and then returns automatically to the base setting 4 9 Calling up O2 Trim Text Messages Switch display to O2 trim 4 10 Displaying the Running Time Meter...

Страница 15: ...g as soon as the burner is in operation with the relevant curve set flame signal is present 4 11 Displaying Checksums and Safety Times 1st safety time oil in seconds 2nd safety time oil in seconds 1st...

Страница 16: ...ia floating contact The burner firing rate controller releases the com bustion internally Combustion is triggered internally by the power control unit 5 3 Range Limits You must set limit values in the...

Страница 17: ...f the control unit reaches the shut down range the base firing rate request is emitted If the control unit s setpoint exceed the shut down range a control shut off occurs This is done by internal proc...

Страница 18: ...oller 5 8 Meaning of the Display Display in FIRING RATE switch position setpoint actual value regular firing rate input internal firing rate Display in mode MANUAL regular firing rate input via channe...

Страница 19: ...TE as BASIC FIRING RATE but ETA MATIC V on SETTING NA POST PURGE AU BURNER OFF no signal present EL SETTING SL CLEAR MEMORY EV SETTING PRE PURGE as PRE PURGE but ETAMATIC V on SETTING ES SETTING CONTR...

Страница 20: ...ignal extinguishes during the first safety time 008 0 0 The flame signal extinguishes during the second safety time 009 0 0 Flame signal does not appear during safety time 010 0 0 Flame signal goes ou...

Страница 21: ...ratio control blocked channel 4 320 1 1 Broken wire at correction input 321 1 1 Broken wire at feedback channel 1 322 1 1 Broken wire at feedback channel 2 323 1 1 Broken wire at feedback channel 3 3...

Страница 22: ...g mode AU 714 0 0 Incorrect signal combination in operating mode BE 715 0 0 Incorrect signal combination in operating mode VO 716 0 0 Incorrect signal combination in operating mode ZP 717 0 0 Incorrec...

Страница 23: ...o 889 0 0 Time interval between remote fault resets is too short 904 1 1 Error in reference of firing rate 911 1 1 Error in reference channel 1 912 1 1 Error in reference channel 2 913 1 1 Error in re...

Страница 24: ...23 6 Appendix 6 3 Calling Up the Condition of the Digital Inputs Meaning of the digital inputs of the ETAMATIC V Switch to digital inputs with keys 16 and 17 Signal applies Signal does not apply...

Страница 25: ...according to IEC 60127 2 Sheet 5 1500A 250VAC Melting Integral I t 40 A s e g Littelfuse 0215002 M XP Fuses that fulfill these requirements are ceramic tube fuses with the marking T2AH 250V Fig 6 3 B...

Страница 26: ...25 6 Appendix 6 5 EU Declaration of Conformity...

Страница 27: ...26 6 Appendix...

Страница 28: ...27 6 Appendix...

Страница 29: ...28 6 Appendix...

Страница 30: ...KG Wiesenstra e 6 D 69190 Walldorf Telefon 49 0 6227 6052 0 Telefax 49 0 6227 6052 57 info lamtec de www lamtec de Publication no DLT2004 20 aEN 022 The information in this publication is subject to t...