Operating Control and Displays
5.4.3
Software Version
Display software version
UI = Software version UI300
BT = Software version BT300
5.4.4
Display of Check Sums
Displaying Check Sums
0 ... 4 = Check sum, access levels 0 ... 4
The checksums are generated from the device parameters. The BT300 calculates one
checksum for the parameters of each access level (0, 1, 2 or 4). The UI300 indicates the
checksums in hexadecimal code.
The checksum shows whether the value of one or more parameters have been changed.