SECTION 1 – GENERAL APPLICATION
•
fixing or fastening work pieces prior to
soldering or other additional processing
•
the placement of spot welding on precious
metal and precious metal alloys, on steel and
steel alloys as well as titanium and various
NE-metals such as
aluminium and brass
•
not authorized for welding teeth fittings
(dental techniques)
•
Operation in outdoor areas is prohibited. Use
in dry room areas only.
No liability of any kind will be assumed for the
durability of welding spots. We recommend
that you always check the spots and to solder
them in case of doubt.
SECTION 2 – INTRODUCTION
PUK111 provides a long-awaited missing link
between difficult joining techniques and laser
welding devices. With the help of an intelligent
combination of high performance electronics and
precision mechanics, we’ve been able to create a
unique spot welding device. It’s small size, low
weight and minimum energy use are important
factors leading to your advantage. Excellent
ignition and welding characteristics allow a broad
range of use. With our welding device, you’re
able to gain access to new dimensions of welding
techniques in the area of production and repair.
SECTION 3 – GENERAL SAFETY INSTRUCTIONS - READ BEFORE USING
3-1. SAFETY INSTRUCTIONS
•
Opening the device is permitted only by
trained experts. Remove the plug before
opening the device and make sure that the
device is without electrical power. Discharge
all device components that may store
electricity.
•
Please consult an expert should any
questions arise. Our customer service team
with expertly trained staff, necessary
resources and equipment would be pleased
to assist you further at any time.
•
Always use original cables that are long
enough and make sure that the clamp
holding the work piece is fastened properly.
•
Hazard conditions may be caused by
electricity as well as by welding current.
•
It is illegal for non-professional electricians to
handle parts that are directly connected to
the mains power supply, except in cases of
pulling the mains plug and/or operating the
main power switch.
•
The device must be disconnected from the
mains as soon as repair or service works is
needed. When leaving the place of work
even for a short time, make sure that the
electrical outlet is blocked clearly.
•
Open circuit voltage is the highest and most
dangerous voltage for welding current. The
highest permitted open circuit voltages are
contained in your national and international
regulations according to the type of welding
current, type of electrical source and the high
or low hazard levels at the workplace.
•
If you believe that operating the device is not
possible without creating hazardous
conditions, then shut off the device and
secure it against unauthorised use. It is clear
that a hazardous conditions are present
when:
o
the device shows visible damage,or
o
or when functional errors occur
o
if it no longer functions properly.
•
Please follow relevant safety measures when