Lampert PUK 111 Скачать руководство пользователя страница 19

PUK 

 

OPTIC DEVICE 115V 

 

Operating Instructions 

 
 

 

 

 

 
Dear Customer, 
 
This handbook is intended to help you with the 
operation of your PUK Optic Device. It is important 
to read the instructions carefully and to follow the 
directions closely in order to avoid disruptions due 
to operating errors. By following instructions 
properly, your equipment will always be ready for 
use and serve you over a long lifespan.  

 
Operation of the device should only be done by 
trained professionals and be operated 
according to the intended purpose of use. The 
manufacturer is in no way responsible for any 
damage caused by improper use and operation. 
Please be sure to read the chapters “General 
Safety Requirements” and “Personal 
Protection” before use.  
 
 
 
 
 
 
 
 
 

 
 
Note on Symbols  

The equipment manufactured by “Lampert Tools 
GmbH“ fulfil the standard requirements of CE 
certification and are manufactured according to 
VDE guidelines. 
The arc welding filter is in conformity with the 
“Practice For Occupational And Educational Eye 
And Face Protection” standard ANSI Z87.1-1989 
(R1998)  
 
Use original parts only for maintenance and 
updating. Our customer service department with 
expertly trained staff, suitable resources and 
equipment would be pleased to help you further.  

 
The device should only be opened or modified 
by authorized customer service technicians, 
otherwise all warrantees and liability claims will 
be void. 

 

 
 

LAMPERT TOOLS GMBH 
August 2003 

Содержание PUK 111

Страница 1: ...Operating Instructions Precision Welding Device PUK 111 and PUK Optic Device Lampert Tools USA Inc 115 V...

Страница 2: ......

Страница 3: ...n Before use please be sure to read the manual sections General Safety Requirements and Personal Protection Please retain these instructions for reference Note on Symbol The equipment manufactured by...

Страница 4: ...Operation and Maintenance 7 4 3 Principal Safety Standards 8 4 4 EMF Information 8 SECTION 5 INSTALLATION 9 5 1 Technical Data 9 5 2 Type Label Chart 9 5 3 Setting Up 10 5 4 Description of Operating...

Страница 5: ...ithout electrical power Discharge all device components that may store electricity Please consult an expert should any questions arise Our customer service team with expertly trained staff necessary r...

Страница 6: ...yourself from electrical strokes open circuit voltage from dangerous rays heat and UV and from hot metal and slags Wear strong and insulated footwear Footwear also must insulate under wet conditions L...

Страница 7: ...trode if you are in contact with the work ground or another electrode from a different machine _ Use only well maintained equipment Repair or replace damaged parts at once Maintain unit according to m...

Страница 8: ...ng cause sparks and flying metal As welds cool they can throw off slag _ Wear approved safety glasses with side shields even under your welding helmet BUILDUP OF GAS can injure or kill _ Shut off shie...

Страница 9: ...p away from moving parts such as fans _ Keep all doors panels covers and guards closed and securely in place H F RADIATION can cause interference _ High frequency H F can interfere with radio navigati...

Страница 10: ...770 3000 website www nfpa org and www sparky org OSHA Occupational Safety and Health Standards for General Indus try Title 29 Code of Federal Regulations CFR Part 1910 Subpart Q and Part 1926 Subpart...

Страница 11: ...bar o Protection class I o Insulation category B o Protection type IP20 o Weight 5 25 kg 5 2 TYPE LABEL CHART Description of symbols Amperes Volts Hertz Alternating Current Direct Current 1 50 60Hz L...

Страница 12: ...T WAIT READY PUK 111 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 Main switch 1 Reset button 2 Charger signal 3 red when charging Ready for use signal 4 green when device is ready for welding Sockets 5 for connectio...

Страница 13: ...crew To connect the microscope plug in the round plug and fasten it as like the optic unit above Attach the pressure controller to the protective gas container after carefully reading the instructions...

Страница 14: ...ll distort the parameter of the device Use only very light pressure on the electrode tip Weld only using low gas pressure 3 to 4 litres 014 cubic feet per minute is often enough Tips Take the time to...

Страница 15: ...re a smooth functioning of your device and guarantee good service in the years to come Occasionally check mains plug and cables and welding cable for damage Check the movable parts of the hand piece f...

Страница 16: ...vice 6 Poor welding characteristics wrong protective gas no protective gas Use inert protective gas ARGON 4 6 7 Oxidation and rust formation Heavy gas pressure sufficient Reduce flow through amount 3...

Страница 17: ...300 Welding table complete with 500mm cable Electrodes 100 400 10 electrodes in display box thoriumoxide free Solder Cross Tweezers 100 750 Solder cross tweezers with 900mm cable Pliers 100 500 Flat p...

Страница 18: ...16 SECTION 9 CONTACT Lampert Tools USA Inc 67 East Madison 512 Chicago IL 60603 Phone 1 866 4 PUK111 1 866 478 5111 Fax 1 312 641 2678 info lampertusa com www lampertusa com...

Страница 19: ...per use and operation Please be sure to read the chapters General Safety Requirements and Personal Protection before use Note on Symbols The equipment manufactured by Lampert Tools GmbH fulfil the sta...

Страница 20: ...PUK Optic Device may only be used when properly connected Use for other than the proper purpose describe is not permitted Use in outdoor areas is not permitted Use only in dry room areas SECTION 2 INT...

Страница 21: ...aviolet rays cause very painful conjunctivital inflammation noticable after several hours Any persons or helpers who are working near the arc should also be made aware of the dangers and be equipped w...

Страница 22: ...Code for Safety in Welding and Cutting CSA Standard W117 2 from Canadian Standards Association Standards Sales 178 Rexdale Boulevard Rexdale Ontario Canada M9W 1R3 phone 800 463 6727 or in Toronto 416...

Страница 23: ...lding table Turn the mains switch 1 to ON During a self test right after switching on the welding device the view protection filter 2 will quickly turn dark and then light Test the device in this mann...

Страница 24: ...ection UV 15 IR protection IR 14 SECTION 6 CARE AND MAINTENANCE 6 1 ROUTINE MAINTENANCE The PUK Optic Device does not require much care or maintenance when used at normal levels However several points...

Страница 25: ...7 SECTION 7 CONTACT Lampert Tools USA Inc 67 East Madison 512 Chicago IL 60603 Phone 1 866 4 PUK111 1 866 478 5111 Fax 1 312 641 2678 info lampertusa com www lampertusa com...