Lampert PUK 111 Скачать руководство пользователя страница 16

14 

 

 

 

7-2. TROUBLESHOOTING CHECK LIST 

 

ERROR CAUSE 

 

SOLUTION 

1. No welding power

 

Mains switch turned on Operation 
signal does not light up

 

 

 

 

 

Interrupted cable 
 

 
Check cable and Mains 

2. No welding power   

Mains switch turned on   
Operation signal green 

Welding cable connection  
interrupted. 
Bad mass or no

 

mass 

Check connections 
Connect work piece

 

 

Fasten contact clamp directly to 
work piece. 

3. No welding power  

Mains switch turned on   
Operation signal constant (red)  

Error by fault current  

Press reset button or switch 
device off and on 
If malfunction continues, send 
device to be serviced  

4. Poor ignition

 

 

 

 

poor contact with mass 
 
dirty electrode  
 
Tip of electrode burnt off  

Connect work piece  
 
Grind electrode  
 
Grind electrode 

5. Mains Fuse and/or safety cut-
out has tripped     

 

Mains fuse too weak, Incorrect 
safety cut out 
 
Mains fuse is tripped under no-
load conditions  

Insert correct fuse 
 
 
Send device to service 

6. Poor welding characteristics 
                                   
 

wrong protective gas  
 
no protective gas  

Use inert protective gas  
(ARGON 4.6) 
 

7.Oxidation and rust formation 

Heavy gas pressure sufficient 
 

Reduce flow through amount – 
3-4 l/min.are 

8. Strong oxidation 
of welding spots  

wrong protective gas  
 
no protective gas 

Use inert protective gas “Argon 
grade 5” (ARGON 4.6) 
 

9. Tungsten  contamination 
in basic material  
 

Electrode with too high 
pressure onto work piece 

Touch work piece with very 
slight pressure so that it 
manages to ignite  

10. Tungsten Electrode

 

sticks to work piece 
 

Electrode with too high 
pressure onto work piece 

Touch work piece with very 
slight pressure so that it 
manages to ignite 

11. Tungsten Electrode 
fuses immediately  
 

Grinding too sharp 

Grind in recommended angle 
(25°) 

12. Static discharge onto the 
device surface 
 

Special situation at your 
location 

Use special foot mat for the 
work area 

13. Workpiece sticks to welding 
table 

Bad contact to welding table 

Use clamp or pliers 

 
ATTENTION: The device should be opened by trained personnel only! 

 
Text and figures at the time of printing. Subject to change. 

 
 
 
 
 
 
 

Содержание PUK 111

Страница 1: ...Operating Instructions Precision Welding Device PUK 111 and PUK Optic Device Lampert Tools USA Inc 115 V...

Страница 2: ......

Страница 3: ...n Before use please be sure to read the manual sections General Safety Requirements and Personal Protection Please retain these instructions for reference Note on Symbol The equipment manufactured by...

Страница 4: ...Operation and Maintenance 7 4 3 Principal Safety Standards 8 4 4 EMF Information 8 SECTION 5 INSTALLATION 9 5 1 Technical Data 9 5 2 Type Label Chart 9 5 3 Setting Up 10 5 4 Description of Operating...

Страница 5: ...ithout electrical power Discharge all device components that may store electricity Please consult an expert should any questions arise Our customer service team with expertly trained staff necessary r...

Страница 6: ...yourself from electrical strokes open circuit voltage from dangerous rays heat and UV and from hot metal and slags Wear strong and insulated footwear Footwear also must insulate under wet conditions L...

Страница 7: ...trode if you are in contact with the work ground or another electrode from a different machine _ Use only well maintained equipment Repair or replace damaged parts at once Maintain unit according to m...

Страница 8: ...ng cause sparks and flying metal As welds cool they can throw off slag _ Wear approved safety glasses with side shields even under your welding helmet BUILDUP OF GAS can injure or kill _ Shut off shie...

Страница 9: ...p away from moving parts such as fans _ Keep all doors panels covers and guards closed and securely in place H F RADIATION can cause interference _ High frequency H F can interfere with radio navigati...

Страница 10: ...770 3000 website www nfpa org and www sparky org OSHA Occupational Safety and Health Standards for General Indus try Title 29 Code of Federal Regulations CFR Part 1910 Subpart Q and Part 1926 Subpart...

Страница 11: ...bar o Protection class I o Insulation category B o Protection type IP20 o Weight 5 25 kg 5 2 TYPE LABEL CHART Description of symbols Amperes Volts Hertz Alternating Current Direct Current 1 50 60Hz L...

Страница 12: ...T WAIT READY PUK 111 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 Main switch 1 Reset button 2 Charger signal 3 red when charging Ready for use signal 4 green when device is ready for welding Sockets 5 for connectio...

Страница 13: ...crew To connect the microscope plug in the round plug and fasten it as like the optic unit above Attach the pressure controller to the protective gas container after carefully reading the instructions...

Страница 14: ...ll distort the parameter of the device Use only very light pressure on the electrode tip Weld only using low gas pressure 3 to 4 litres 014 cubic feet per minute is often enough Tips Take the time to...

Страница 15: ...re a smooth functioning of your device and guarantee good service in the years to come Occasionally check mains plug and cables and welding cable for damage Check the movable parts of the hand piece f...

Страница 16: ...vice 6 Poor welding characteristics wrong protective gas no protective gas Use inert protective gas ARGON 4 6 7 Oxidation and rust formation Heavy gas pressure sufficient Reduce flow through amount 3...

Страница 17: ...300 Welding table complete with 500mm cable Electrodes 100 400 10 electrodes in display box thoriumoxide free Solder Cross Tweezers 100 750 Solder cross tweezers with 900mm cable Pliers 100 500 Flat p...

Страница 18: ...16 SECTION 9 CONTACT Lampert Tools USA Inc 67 East Madison 512 Chicago IL 60603 Phone 1 866 4 PUK111 1 866 478 5111 Fax 1 312 641 2678 info lampertusa com www lampertusa com...

Страница 19: ...per use and operation Please be sure to read the chapters General Safety Requirements and Personal Protection before use Note on Symbols The equipment manufactured by Lampert Tools GmbH fulfil the sta...

Страница 20: ...PUK Optic Device may only be used when properly connected Use for other than the proper purpose describe is not permitted Use in outdoor areas is not permitted Use only in dry room areas SECTION 2 INT...

Страница 21: ...aviolet rays cause very painful conjunctivital inflammation noticable after several hours Any persons or helpers who are working near the arc should also be made aware of the dangers and be equipped w...

Страница 22: ...Code for Safety in Welding and Cutting CSA Standard W117 2 from Canadian Standards Association Standards Sales 178 Rexdale Boulevard Rexdale Ontario Canada M9W 1R3 phone 800 463 6727 or in Toronto 416...

Страница 23: ...lding table Turn the mains switch 1 to ON During a self test right after switching on the welding device the view protection filter 2 will quickly turn dark and then light Test the device in this mann...

Страница 24: ...ection UV 15 IR protection IR 14 SECTION 6 CARE AND MAINTENANCE 6 1 ROUTINE MAINTENANCE The PUK Optic Device does not require much care or maintenance when used at normal levels However several points...

Страница 25: ...7 SECTION 7 CONTACT Lampert Tools USA Inc 67 East Madison 512 Chicago IL 60603 Phone 1 866 4 PUK111 1 866 478 5111 Fax 1 312 641 2678 info lampertusa com www lampertusa com...

Отзывы: