EXPANDING YOUR TRACER

Interchangeable electrodes are available to convert the Total Chlorine TRACER 

to a pH TRACER or an ORP TRACER.
Remember to ask for instructions and appropriate reagent or buffer tablets when 

ordering pH or ORP electrodes.

pH TRACER Electrode, 0.00-14.00 pH

Code 1733

The pH TRACER Electrode is used with pH 4.0, 7.0

and 10.0 buffers. Order using the following codes:
pH 4.0 Mini Buffer Tablets (100)

Code 3983A-J

pH 7.0 Mini Buffer Tablets (100)

Code 3984A-J

pH 10.0 Mini Buffer Tablets (100)

Code 3985A-J

ORP TRACER Electrode,±999 mV

Code 1734

The ORP TRACER Electrode (code1734) requires

an initial soaking in a pH 4.0 buffer solution. Order

pH 4.0 Mini Buffer Tablets/100 pack (Code 3893A-J).

WARRANTY

The TRACER PocketTester is specif cally calibrated for use with the TRACER 

TC1 Tablets (Code 7044A). Use with other reagent systems will void the warranty 

and may damage the meter.
LaMotte Company warrants this instrument to be free of defects in parts and 

workmanship for 1 year from the date of shipment and the probe to be free of 

defects in parts and workmanship for 6 months from the date of shipment. If it 

should become necessary to return the instrument for service during or beyond 

the warranty period, contact our Technical Service Department 

The sender is responsible for shipping charges, freight, insurance and proper 

packaging to prevent damage in transit. This warranty does not apply to defects 

resulting from action of the user such as misuse, improper wiring, operation 

outside of specif  cation, improper maintenance or repair, or 

unauthorized 

modif  cation. LaMotte Company specif  cally disclaims any implied warranties 

or merchantability or f  tness for a speci f  c purpose and will not be liable for 

any direct, indirect, incidental or consequential damages. LaMotte Company’s 

total liability is limited to repair or replacement of the product. The warranty 

set forth above is inclusive and no other warranty, whether written or oral, is 

expressed or implied. 

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176

 TestEquipmentDepot.com 

Содержание Tracer Total Chlorine PockeTester 1740

Страница 1: ...Water Testing Leader Since 1919 Tracer Total Chlorine PockeTesterTM Code 1740 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com...

Страница 2: ...WARNING This set contains chemicals that may be harmful if misued Read cautions on individual containers carefully Not to be used by children except under adult supervision...

Страница 3: ...ging the Display Temperature Units 6 Low Battery Indicator 6 Testing Conditioning the Electrode 7 Measurement 7 Storing Readings 7 Recalling Stored Readings 8 For Best Accuracy 8 Offset Adjustment Pro...

Страница 4: ...buffer be added to the sample before testing SPECIFICATIONS Display Multifunction display with bar graph Operating conditions 32 to 122 F 0 to 50 C and 80 RH Chlorine range 0 01 to 10 00 ppm Total Ch...

Страница 5: ...compartment cover 2 LCD Display 3 MODE HOLD button 4 CAL RECALL button 5 ON OFF button 6 Electrode Retaining Collar ring 7 Electrode Sensor Note The Electrode storage cap is not shown LCD Display 1 B...

Страница 6: ...R is turned on it will automatically self calibrate and the SELF and CAL icons will be displayed These icons will disappear after the self calibration is complete The main display and bar graph will t...

Страница 7: ...and the electrode must remain still and stable during the entire measurement 7 The display will f ash while readings are changing rapidly The result should be read when the display stabilizes The read...

Страница 8: ...use 3 If measuring solutions with large differences in chlorine concentration for example 0 1 ppm and 5 0 ppm use a separate sample cup for each concentration 4 Discard the sample cup when it becomes...

Страница 9: ...oximately 5 seconds until C_O appears at the bottom of the display 5 IMMEDIATELY press the MODE HOLD button repeatedly to increase the value or press the CAL RECALL button repeatedly to decrease the v...

Страница 10: ...1 00 mL of the 10 000 ppm standard into another 100 mL volumetric f ask Dilute to the 100 mL line with deionized water Cap and mix This standard is 100 ppm 3 Pipet exactly 1 00 mL of the 100 ppm solu...

Страница 11: ...splayed keep the electrode in standard and press the CAL key again until CAL is displayed then press the CAL and MODE keys again simultaneously Immediately release both keys 9 After approximately 5 to...

Страница 12: ...tabs 3 Replace the four CR2032 batteries Observe polarity 4 Replace the battery compartment cap Cleaning the Electrode The TRACER Chlorine Electrode arrives in a factory cleaned condition and is read...

Страница 13: ...meter to malfunction 5 Firmly tighten the electrode collar to create a seal with the rubber gasket between the electrode and the meter Do not over tighten 6 Cover the connector end of the removed ele...

Страница 14: ...ment to be free of defects in parts and workmanship for 1 year from the date of shipment and the probe to be free of defects in parts and workmanship for 6 months from the date of shipment If it shoul...

Отзывы: