Methods of Extraction          

 

 

 

  

The very best method of clearing the kitchen of unwanted odours is by connecting the appliance to an 

exhaust duct and venting to the outside atmosphere via the ceiling or an exterior wall. (Suitable ducting kits 

may be purchased from the depot where you bought the extractor.) You do not need charcoal 

 when 

using the external ducting mode.

Filtered air 

recirculated

Ducting kit (APL2805/6/7)

Supplied Separately

Vent through external

 wall or ceiling

Fig 1. 

Ducting mode 

(No charcoal 

 required) 

Fig 2.

Recirculation mode

(Charcoal 

 HJA29

06

 required)

Extraction Via Ducting    

              

Never use the hood in areas where devices with 

exhaust pipes connected to the outside are 

already operating unless perfect ventilation can be 

guaranteed.

• 

Connect the external ducting kit to the outlet 

of the extractor.

Charcoal 

 are not required if the extractor 

is to be ducted out. 

Extraction Via Recirculation                

For extraction via recirculation, attach 2 charcoal 

 to the sides of the motor inside the hood.

These can be ordered separately quoting part 

reference HJA29

06

  

switched off.

  

• 

Remove the grease 

 

• 

Align the carbon 

 over the pins located 

on either side of the fan motor.

• 

Turn the carbon gently, until you feel them 

click into position.

• 

Replace the grease 

 before the power 

supply it turned back on.

Installation

We recommend you turn the extractor on 

5-10 minutes before cooking for maximum 

efficiency of operation.

Содержание LAM2504

Страница 1: ...Instructions and Installation LAM2504 Black Curved Glass Chimney Extractor www howdens com appliance registration...

Страница 2: ...See back page for product serial number...

Страница 3: ...ing for possible hazards to health and property Warning possibility of electric shock This appliance is marked according to the European Directive 2012 19 EU on Waste Electrical and Electronic Equipme...

Страница 4: ...Extractor Layout 06 Control Panel Layout 06 Care and maintenance 07 General Cleaning 07 Grease Filters 07 Carbon Filters 08 Replacing the Lamps 08 Installation 09 Methods of Extraction 09 Extraction...

Страница 5: ...the product when your judgment or coordination is impaired by the use of alcohol and or drugs Product must be disconnected from the mains during installation maintenance cleaning and repair procedures...

Страница 6: ...est point on the hob top including the burners and the bottom of the cooker hood m m 0 0 7 s r e k o o C c i r t c e l E m m 0 0 7 s r e k o o C s a G m m 0 0 8 s r e k o o C l i O l a o C Never flamb...

Страница 7: ...wer Chimney Section 4 Fan and Light Controls 5 Extractor Body 6 Grease Filters 7 Light 8 Glass Canopy General Information Operation 0 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 Extractor layout Control Panel Layou...

Страница 8: ...abrasive cleaners Do not use a steam cleaner to clean the hood electrical components could be damaged or short circuit as a result The Grease Filters Clean the filter every month an excessive build up...

Страница 9: ...tly Replacing the Lamps The extractor hood is with x2 LED lamp units that must only be replaced by a suitably qualified person The lights are powered by an electronic driver device and neither part is...

Страница 10: ...Ducting Never use the hood in areas where devices with exhaust pipes connected to the outside are already operating unless perfect ventilation can be guaranteed Connect the external ducting kit to the...

Страница 11: ...ill the extractor body a two piece telescopic decorative chimney a bag of wall and screws two brackets a ducting connector and reducer 1 Main Extractor Body 2 Lower Chimney 3 Upper Chimney 4 Upper Fix...

Страница 12: ...uate room ventilation is provided when the extractor is used in the same room as appliances supplied with energy other than electricity Never duct into a hot air such as a central heating duct 320mm 7...

Страница 13: ...kit if venting externally 4 Rest the chimney sections on the main extractor body and extend the upper section to the ceiling 5 Use the extended chimney sections to mark up the appropriate position of...

Страница 14: ...labelled LOAD are for connection to the appliance IMPORTANT The wires in the mains lead are coloured in accordance with the following code Blue Neutral Brown Live Green Yellow Earth As the colours of...

Страница 15: ...re any venting is not obstructed Clean the grease with warm water and mild detergent and or replace any charcoal The extractor works normaly but smells linger Clogged can reduce the product s and may...

Страница 16: ...ed for normal domestic purposes This guarantee does not cover accidental damage misuse or alterations which are likely to affect the product The guarantee is invalid if the product is tampered with or...

Страница 17: ...64 lux 0 W 56 dB In order to reduce the environmental impact e g energy use of the cooking process please be sure that your product is installed according to the user manual Ensure adequate ventilatio...

Страница 18: ...Product serial number Place sticker here ISSUE v2 290917...

Отзывы: