background image

www.howdens.com

Page _ 11

LAMONA 

Appliances

Hanging Your Extractor               

  

This instruction must be strictly adhered to. Failure to comply could result in overheating and  

 

serious damage to your appliance. It is recommended that the installation is carried out by two people.

Before drilling or chiselling the ceiling or wall, check for pipes and power cables.

• 

If ducting externally ensure the ducting tube is kept as short as possible and with the minimum 

of bends to permit the smoothest 

 (Maximum length 3 metres.). Ducted air must not be 

discharged into a 

 which is used for exhausting fumes from appliances supplied with energy other 

than electricity. (E.g. gas boilers)

• 

Ensure the requirements of the local authorities are adhered to concerning the discharge of exhaust 

air.

• 

Ensure adequate room ventilation is provided when the extractor is used in the same room as 

appliances supplied with energy other than electricity.

• 

Never duct into a hot air 

 such as a central heating duct

320mm

700 mm Minimum distance to worktop

750 mm Recommended distance to worktop

**  

**

**

**

**

**

Worktop

Wall

73mm

(**) 

Please use rawl plugs and screws appropriate 

to the type of wall (not supplied) 

700 mm Minimum distance to worktop

750 mm Recommended distance to worktop

40 mm 

260 mm 

219 mm 

Please use rawl plugs and screws 

appropriate to the type of wall 

Wall

 = 

 = 

2

1

2

3

1.  Remove the grease 

 before trying to install.

2.  The recommended 

 height for the hood is 750mm above the worktop. This can be reduced to a 

minimum of 700mm if required.

3.  Mark and drill the holes required to mount the extractor body. 

4.  The principal securing points are the 2 key holes; fix this first.

 

 

 

 is 

 

5.  With the help of an assistant, hang the extractor body on the screws level and secure in position 

through the lower two .

254 mm   = 

 = 

Содержание LAM2504

Страница 1: ...Instructions and Installation LAM2504 Black Curved Glass Chimney Extractor www howdens com appliance registration...

Страница 2: ...See back page for product serial number...

Страница 3: ...ing for possible hazards to health and property Warning possibility of electric shock This appliance is marked according to the European Directive 2012 19 EU on Waste Electrical and Electronic Equipme...

Страница 4: ...Extractor Layout 06 Control Panel Layout 06 Care and maintenance 07 General Cleaning 07 Grease Filters 07 Carbon Filters 08 Replacing the Lamps 08 Installation 09 Methods of Extraction 09 Extraction...

Страница 5: ...the product when your judgment or coordination is impaired by the use of alcohol and or drugs Product must be disconnected from the mains during installation maintenance cleaning and repair procedures...

Страница 6: ...est point on the hob top including the burners and the bottom of the cooker hood m m 0 0 7 s r e k o o C c i r t c e l E m m 0 0 7 s r e k o o C s a G m m 0 0 8 s r e k o o C l i O l a o C Never flamb...

Страница 7: ...wer Chimney Section 4 Fan and Light Controls 5 Extractor Body 6 Grease Filters 7 Light 8 Glass Canopy General Information Operation 0 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 Extractor layout Control Panel Layou...

Страница 8: ...abrasive cleaners Do not use a steam cleaner to clean the hood electrical components could be damaged or short circuit as a result The Grease Filters Clean the filter every month an excessive build up...

Страница 9: ...tly Replacing the Lamps The extractor hood is with x2 LED lamp units that must only be replaced by a suitably qualified person The lights are powered by an electronic driver device and neither part is...

Страница 10: ...Ducting Never use the hood in areas where devices with exhaust pipes connected to the outside are already operating unless perfect ventilation can be guaranteed Connect the external ducting kit to the...

Страница 11: ...ill the extractor body a two piece telescopic decorative chimney a bag of wall and screws two brackets a ducting connector and reducer 1 Main Extractor Body 2 Lower Chimney 3 Upper Chimney 4 Upper Fix...

Страница 12: ...uate room ventilation is provided when the extractor is used in the same room as appliances supplied with energy other than electricity Never duct into a hot air such as a central heating duct 320mm 7...

Страница 13: ...kit if venting externally 4 Rest the chimney sections on the main extractor body and extend the upper section to the ceiling 5 Use the extended chimney sections to mark up the appropriate position of...

Страница 14: ...labelled LOAD are for connection to the appliance IMPORTANT The wires in the mains lead are coloured in accordance with the following code Blue Neutral Brown Live Green Yellow Earth As the colours of...

Страница 15: ...re any venting is not obstructed Clean the grease with warm water and mild detergent and or replace any charcoal The extractor works normaly but smells linger Clogged can reduce the product s and may...

Страница 16: ...ed for normal domestic purposes This guarantee does not cover accidental damage misuse or alterations which are likely to affect the product The guarantee is invalid if the product is tampered with or...

Страница 17: ...64 lux 0 W 56 dB In order to reduce the environmental impact e g energy use of the cooking process please be sure that your product is installed according to the user manual Ensure adequate ventilatio...

Страница 18: ...Product serial number Place sticker here ISSUE v2 290917...