14
www.howdens.com
N
L
L
N
LOAD
SUPPLY
LOAD
SUPPLY
DP
13A 250V~
FUSE
ON
Blue.
(Neutral)
Brown.
(Live)
Electrical connections
IMPORTANT: Ensure that the electricity
supply is switched off before connecting.
and securely held in place or a cable grid is
back into the motor cavity.
wiring via the use of a double pole switched
fused spur outlet with at least 3mm contact
separation, the isolation switch must be
accessible after installation. (See technical
The appliance should be connected by a
be installed in accordance with all local
regulations.
The terminology DOUBLE POLE -/+
means that both the live and neutral supplies
are switched and disconnected at the same
time.
The terminations labelled SUPPLY are the
connections for the internal house wiring
and the terminations labelled LOAD are for
connection to the appliance.
IMPORTANT: The wires in the mains lead are
coloured in accordance with the following
code:-
Blue.....................Neutral
Brown..................Live
Green/ Yellow.....Earth
As the colours of the wires in the mains
lead of this appliance may not correspond
with the coloured markings identifying
the terminals in your spur box, proceed as
follows;
The wire which is coloured blue must be
connected to the terminal which is marked
with the letter ‘N’ or coloured BLACK. The
wire which is coloured brown must be
connected to the terminal which is marked
with the letter ‘L’ or coloured RED. The wire
which is coloured Green and Yellow must be
connected to the terminal which is marked
with the letter ‘E’ or
symbol.
Green & Yellow.
(Earth)