manualshive.com logo in svg
background image

Operating and installation instructions

Cooker hoods
DA 216-2, DA 216-2 EXT
DA 217-2
DA 219-2, DA 219-2 EXT

It is 

essential

 to read these

operating instructions before

GiWOZ

installing or using the machine,
to avoid the risk of accidents 
or damage to the machine.

 M.-Nr. 05 609 490

Содержание DA 216-2

Страница 1: ...ns Cooker hoods DA 216 2 DA 216 2 EXT DA 217 2 DA 219 2 DA 219 2 EXT It is essential to read these operating instructions before GiWOZ installing or using the machine to avoid the risk of accidents or damage to the machine M Nr 05 609 490 ...

Страница 2: ...g the filter operating hours counter 13 Altering the filter operating hours counter 14 Cleaning and care Housing 16 Grease filters 17 Fitting replacing the active charcoal filters 18 Changing a light tube 19 Appliance dimensions 20 Installation Assembly parts 22 Retaining plates 24 Canopy 26 Motor unit 27 Control unit 28 Electrical connection 28 Air extraction 29 Recirculation 30 Extension piece 3...

Страница 3: ...ren Danger of suffocation Rather than just throwing these materials away please ensure they are offered for recycling Disposal of your old appliance Old appliances may contain material which can be reclaimed or recycled Please contact your dealer your local waste collection centre or scrap mer chant about potential recycling schemes Ensure that the appliance presents no danger to children while be...

Страница 4: ...ust correspond in order to avoid risk of damage to the appliance Consult a qualified electrician if in doubt The electrical safety of this ap pliance can only be guaranteed when continuity is complete between the appliance and an effective earthing system which complies with local and national regulations It is most import ant that this basic safety requirement is tested by a qualified electrician...

Страница 5: ...e are always covered by a pan Otherwise flames could be drawn up by the suction of the cooker hood parts of which could then be damaged Always switch the cooker hood on when using the hob otherwise con densation may collect in the hood which could cause corrosion When cooking with oil or fat chip pans and deep fat fryers etc do not leave the pans unattended Never leave an open grill unattended whe...

Страница 6: ...ce is fitted be neath the cooker hood and they have different minimum safety distances to the cooker hood select the greater distance Safety regulations prohibit the fitting of a cooker hood over solid fuel stoves All ducting pipework and fittings must be of non flammable ma terial These can be obtained from the Miele Spare Parts department or from builders merchants The appliance must not be con ...

Страница 7: ...ractor can only be switched on when the heating ap pliance is switched off or vice versa N B The overall ventilation condition of the dwelling must be taken into ac count If in any doubt the advice of a competent builder or for gas a Corgi installer must be sought If the cooker hood is operated in recir culation mode with active charcoal filter then the above restrictions do not apply Appliances w...

Страница 8: ...Description of the appliance Description of the appliance 8 ...

Страница 9: ...w how long the grease filter has been in use see section on Operation Filter operating hours counter to alter the number of hours counted by the filter operating hours counter see section Operation Altering the filter operating hours counter o Touch control for the active charcoal filters The indicator lamp above the active charcoal filter touch control lights up when the recirculation mode active...

Страница 10: ...rculation The air is drawn in and cleaned first by grease filters and then cleaned by ac tive charcoal filters The cleaned air is then recirculated back into the kitchen through a vent in the top of the cooker hood extension piece Before using the cooker hood for the first time ensure that the active charcoal filters are in place see section on Cleaning and care an external fan The EXT models are ...

Страница 11: ...ontrol lower setting Depending on the intensity of cooking vapours levels I to III green indica tor lamp are usually sufficient for nor mal cooking Intensive setting When frying or cooking food with a strong aroma you may wish to select the Intensive setting yellow indicator lamp for a short period Run on option If the air still needs to be cleared after cooking the cooker hood can be set to conti...

Страница 12: ...l to switch on the hob illumination The indicator lamp above the touch control lights up To switch the lighting off Briefly press the hob illumination con trol to switch the lighting off The indicator lamp above the control goes out Safety cut out Should the cooker hood have been left switched on the fan will switch off auto matically after 10 hours The lighting re mains on Pressing the On Off tou...

Страница 13: ... has operated for the number of hours set The active char coal filters must then be replaced with new ones After new active charcoal filters have been put in place the filter operating hours counter must be re set Press the active charcoal filter touch control for about 3 seconds The indicator lamp will go out Reading the filter operating hours counter To check the percentage of time set already u...

Страница 14: ...ng more difficult Procedure Press the On Off touch control to switch the fan off Press the run on option touch control and the grease filter touch control at the same time The indicator lamp above the grease fil ter touch control and one of the lamps above the touch controls will flash The touch control lamps show the time which has been set 1st lamp from the left 20 hours 2nd lamp from the left 3...

Страница 15: ...un on option touch control and the active charcoal filter touch control at the same time The indicator lamp above the active charcoal filter touch control and one of the lamps above the touch controls will flash The touch control lamps show the time which has been set 1st lamp from left 120 hours 2nd lamp from left 180 hours 3rd lamp from left 240 hours 4th lamp from left unlimited Use the touch c...

Страница 16: ... damage Avoid cleaning agents containing soda acids or chlorides abrasive cleaning agents e g pow der cleaners or cream cleaners abrasive sponges e g pot scourers or sponges which have been pre viously used with abrasive cleaning agents These will damage the surface material Stainless steel Stainless steel surfaces can be cleaned using a proprietary non ab rasive cleaning agent designed specifi ca...

Страница 17: ... discolouration to the surface of the filters However this will not affect the func tioning of the grease filters in any way After cleaning leave the filters to dry on an absorbent surface before put ting them back in place When removing the filters for clean ing also clean off any residues of oil or fat from the now accessible hous ing to prevent the risk of these catch ing fire When replacing th...

Страница 18: ...tructions Ensure these are carefully followed When fitting for the first time Set the operating hours counter to suit your requirements see Oper ation Altering the filter operating hours counter Always replace the filters immediately if the lamp for the active charcoal filter touch control comes on or if they are no longer effective in absorbing kitchen odours They should however be replaced at le...

Страница 19: ...is removed in countries where this is applicable Unscrew the fixing screw of either the right or left hand holder for the glass cover When doing this push the glass cover upwards so that it does not fall on the hob surface Take off the glass cover holder Then take out the glass cover guid ing it downwards at an angle Carefully lower the light tube down wards and pull out Change the light tube and ...

Страница 20: ...Appliance dimensions Appliance dimensions 20 ...

Страница 21: ...e ceiling make sure that the remaining distance to the ceiling is not greater or less than ap pliance height H Appliance height H DA 216 2 Extraction and EXT 700 940 mm Recirculation 790 1025 mm DA 217 2 Extraction 710 950 mm Recirculation 800 1035 mm DA 219 2 Extraction and EXT 730 970 mm Recirculation 820 1055 mm With air extraction to the rear through a wall the total height must be at least 79...

Страница 22: ...Installation Assembly parts Installation 22 ...

Страница 23: ...into the exhaust socket on the motor unit for ex traction mode only not on EXT models j 1 exhaust connection for fitting in the canopy only with EXT models k Upper retaining plate B for secur ing the extension piece l Middle retaining plate C for addi tional stability of the tower m Lower retaining plate A for secur ing the canopy and the motor unit 12 large headed screws 5 x 40 mm and 12 S 8 plug...

Страница 24: ...surface upwards see Appliance dimensions This marks the height of the lower rim of the cooker hood DA 216 2 EXT 217 2 Drill an 8 mm ø hole on the middle line 18 mm above the height marked S Insert an S8 plug into the hole DA 219 2 EXT Drill two 8 mm ø holes 18 mm above the height marked S and 250 mm right and left of centre Insert S8 plugs Retaining plate A Drill two 8 mm ø holes one at S 100 mm a...

Страница 25: ...taining plate B Hold retaining plate B to the wall and push up until it is directly below the ceiling Use the notches and the middle line to align it horizontally Mark the 2 drill holes on the wall Drill two 8 mm ø holes into the wall and push the S8 plugs into the holes Screw on the retaining plate with two 5 x 40 mm screws Retaining plate C Retaining plate C only needs to be fitted if dimension ...

Страница 26: ...late C with two 5 x 40 mm screws Canopy Before fitting the canopy the glass cover of the lighting tube must first be removed see relevant section in Cleaning and care Hang the canopy on the angle brackets on retaining plate A Secure the canopy Secure the ca nopy with 5 x 40 mm screws into each drilled hole DA 216 2 EXT 217 2 Secure the canopy with a 5 x 40 mm screw DA 219 2 EXT Secure the canopy w...

Страница 27: ...ducting has to be used the reducing collar needs to be fitted into the exhaust connec tion on the motor unit see Connection for air extraction With recirculation mode Fit the reducing collar onto the ex haust connection The non return flap is not required First loosely screw the two locking nuts onto the threaded bolts on re taining plate A Leave a gap of approx 3 mm for hanging the motor on after...

Страница 28: ... x 13 mm screws On EXT model cooker hoods the con trol unit is fitted instead of the motor unit and then secured with self lock ing nuts Electrical connection Connect the canopy connection cable to the corresponding coup lings on the left and right of the motor unit or control unit Do this by connecting the four pole plug into the rear connection of the coupling on the left of the motor unit or co...

Страница 29: ...nnecting the appliance read the safety notes in Warning and Safety Instructions and in the Electrical connection section Air extraction For extraction connection secure a flexible hose or an extraction pipe to the exhaust connection on the motor unit using a hose clip Lead the top end to the open air or to the external fan through the wall or ceiling cut out For further installation instructions p...

Страница 30: ...ters necessary for recirculation are available from the Spare Parts De partment or your dealer Extension piece An extension piece allows the cooker hood to be fitted at varying distances from the ceiling see section appliance dimensions The extension piece has openings at each side These are needed for venti lation when the appliance is being used in recirculation mode Recirculation Extraction For...

Страница 31: ...ate For recirculation make sure that the openings in the extension piece are po sitioned at the same height as the air outlets in the directional unit of the fan motor Screw the extension piece firmly to the upper retaining plate at each side with two 3 9 x 7 5 mm screws Only with recirculation mode Fit the recirculation grilles into the extension piece and into the directional unit be hind so tha...

Страница 32: ...ts Stick the protective sheet to the ex tension piece so that it is smooth at the sides and flush at the bottom Fitting the tower Before fitting remove the protective foil A protective cardboard sheet protects the tower from accidental scratching during fitting Remove the protective foil from around the sticking points Attach the protective sheet to the front of the tower so that it protrudes slig...

Страница 33: ...py Adjust the tower Remove the protective sheets Now secure the tower on both sides with two 3 9 x 7 5 mm screws Remove the protective foil from the canopy Before using the appliance for the first time take the grease filter out and remove the protective foil from the filter frame Then replace the filter Installation 33 ...

Страница 34: ... level of the cooker hood would increase and extraction would be less effi cient Only reduce the diameter of the duct ing if absolutely necessary e g where narrower ducting has already been installed Only use wide radius bends Tight bends reduce the air throughput of the cooker hood Only use smooth pipes or flexible hoses made from non flammable ma terials for extraction connection Where ducting i...

Страница 35: ...be addressed The exhaust ducting will need to be suitably insu lated Condensate trap In addition to insulating the exhaust ducting we recommend that a suitable condensate trap is also installed to collect and evaporate any condensate which may occur When installing a condensate trap ensure that it is positioned vertically and if possible directly above the exhaust connection Connection for air ext...

Страница 36: ...in stallation depending on country an ad ditional means of disconnection must be provided for all poles For extra safety it is advisable to install a residual current device RCD with a trip current of 30 mA in accordance with DIN VDE 0664 VDE 0100 Section 739 Do not connect via an extension lead Important UK If the appliance is fitted with a non re wireable plug BS 1363 UK and the socket outlets a...

Страница 37: ...een and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth sym bol z or coloured green or green and yellow The wire which is coloured blue must be connected to the terminal which is marked with the letter N or col oured black For U K IRL ZA The wire which is coloured brown must be connected to the terminal which is marked with the letter L or col...

Страница 38: ...Department see back cover for address When contacting the Service Depart ment please quote the model and ser ial number of your appliance These are shown on the data plate which is visible when the grease filters are removed Please note that telephone calls may be monitored and recorded to improve our service After Sales Service 38 ...

Страница 39: ...1591 Extraction system ø 150 mm Level I 220 m3 h Level II 335 m3 h Level III 440 m3 h Intensive level 640 m3 h Extraction system ø 125 mm Level I 210 m3 h Level II 305 m3 h Level III 405 m3 h Intensive level 590 m3 h unrestricted 690 m3 h Recirculation with charcoal filter Level I 180 m3 h Level II 290 m3 h Level III 390 m3 h Intensive level 485 m3 h Active charcoal filter Miele active charcoal fi...

Страница 40: ...Alteration rights reserved 44 000 GB IRL AUS NZ ZA 1301 This paper consists of cellulose which has been bleached without the use of chlorine ...

Отзывы: