lnstal lation
r
ecommendations
You should install equipment where:
•
Flat, stable floor
Inclined or unstable floor may cause the equipment not to work correctly, leading to poor quality lamination.
•
Dedicated use of power receptacle
Use a receptacle that can be used exclusively for the equipment. Do not use power other than the rating
of
voltage specified in this User Manual. Ground the equipment, and insert a circuit breaker between the
equipment and mains power supply.
•
Ample space for the operation
of setting up laminate film and materials and taking the laminated product out of the equipment.
•
Dry, well-ventilated area
Humid environment may cause short-circuit or other failures to occur.
Avoid installing the equipment outdoors, or other locations where the environment can be considered outdoor,
or indoor space subject to direct sun
light
or direct exposure to air conditioner's air
flow.
Temperature : 50
o
- 90
o
F
Humidity: 20 - 60%
Even in the case of satisfactory location that can satisfy the conditions shown above, the equipment may
not work properly dependent o
n
the type and nature of the laminate films and material to be laminated.
The operating environment should be appropriate for the laminate films and material
used.
•
Operability
For convenience of normal use and maintenance, there should be the following space around the equipment.
•
Front: at least 20" (for laminating 11" x 17" papers)
·
Rear: at least 20" (for laminating 11" x 17" papers)
·
Both sides: at I east 4"
05
20 "
12"
20"
4"
4"
22"
Leon13DX
Содержание Leon13DX