2.7.2  Power and signal connection

The sensor u[sonic]WS7 Modbus requires a 4-pole M12 plug 

connector. The cable shield should be connected with both 

ends at the ground wire (PE).

T

o reduce the risk of inductive interference a properly 

grounding of the sensor is recommended.

The external connection is via central connector which is 

located in housing base. For further details about electrical 

connection please see chapter „Connecting diagrams“. 

If the sensor is mounted in correct manner and connected 

with the right cable (accessory), you can attach the wires to 

power supply and signal outputs to data acquisition equipment 

(computer). 

The typical power supply requirements of the u[sonic]WS7 is 

24 VDC with a typical current drain of 50 mA. The input range 

is 6...60 VDC or 12...42 VAC.

 

The heater of the u[sonic]WS7 

has to be supplied with 24 V AC/DC. In standard configuration 

the heating power is 60 W with a current drain of 2.5 A at 

24 VDC. 

The line drivers are capable of transmitting data over cable 

lengths up to 1,220 meters (4,000 feet). This maximum dis-

tance will vary depending on the quality of the used cables. 
When the power supply of the sensor is switched on, after 

2 seconds the sensor cyclically starts sending data protocols.

2.7.3  Safety regulations

Because the wind sensor often is mounted on ex-

posed locations in dangerous heights the installation 

personnel has to pay attention to the relevant safety 

regulations for such works. During the electrical 

installation and termination works the external circuit-

breaker must be switched off. It is not permitted to 

open those housings by unauthorized persons!

3 Maintenance

3.1 

Regular maintenance and calibration

The sensor u[sonic]WS7 is service reduced and designed for 

a very long lifetime. Recommended is a regular visual check 

regarding dirt of surface caused by the weather and if so, to 

clean up. The radiation sensor glass dome should be cleaned 

with a soft towel at least every 2 weeks. For stubborn stains, 

the glass dome can be handled with soapy water or alcohol.

If reference measurements should be necessary 

stringently must be noted that a comparability of the 

measured values is given only if the measurements 

take place under same conditions. I.e. the reference 

equipment must be used very close to the sensor!

The sensor is a measuring instrument and thus apply user 

specific standards regarding period of recalibration. 

Recommendation: 2 years.

3.2 

Visual check and cleaning

The use of the sensor under the respective environmental 

conditions requires certain steps. It is thus recommendable 

to clean the outside of the housing and shelter within specific 

intervals. The intervals are dependant on the environmental 

conditions and the degree of soiling. We recommend a regular 

sight and functional check.

In case you should be faced with any specific problems please 

contact the LAMBRECHT meteo service under:
Tel.: +49-(0)551-4958-0
Fax: +49-(0)551-4958-312
E-Mail: [email protected]

4 Transports

In case it is necessary to ship or to transport the sensor must 

be carefully packed to prevent damages during transport.

5

Содержание meteo WS6

Страница 1: ...n and display of the measured values using the MeteoWare CS evaluation software Easy space saving mounting on 50 mm standard pipe The Perfect Weather Sensor For industrial use as well as under extreme...

Страница 2: ...the appropriate disposal of waste electronic equipment Content 1 Introduction 3 1 1 Warranty 3 2 Setting to work 3 2 1 Installation conditions 3 2 1 1 Generally 3 2 2 Tools and installation aids 4 2...

Страница 3: ...ring elements This heating is particularly effective against ice and snow in all climatic zones The measuring principle allows very low starting values and high repeat accuracy The sensor rapidly can...

Страница 4: ...he two grup screws Finally the earth screw has to be connected to the ship s ground Acid free contact grease is recommended to protect contact surfaces against corrosion Note Follow all safety instruc...

Страница 5: ...t safety regulations for such works During the electrical installation and termination works the external circuit breaker must be switched off It is not permitted to open those housings by unauthorize...

Страница 6: ...ilization and communication of it s contents prohibited unless definitely permitted Infringement is bound to compensation All rights reserved for patent or registered pattern Ma e ohne Toleranzangabe...

Страница 7: ...r than a single byte that the most significant byte is sent first Example Big Endian Register size value 16 bits 0x1234 is transmitted in the sequence 0x12 0x34 To obtain the real measuring value divi...

Страница 8: ...10 1 Read only 30003 Wind speed maximum m s 10 1 Read only 30004 Wind speed minimum m s 10 1 Read only 30202 Wind direction average 10 1 Read only 30203 Wind direction maximum 10 1 Read only 30204 Wi...

Страница 9: ...n Read Input Register 4 Func Desk Byte count 2 Data 00 14 Checksum OK 3FB9 6 7 Descriptive sensor parameter registers Holding Register Register Parameter name Quantity of registers Remark Access type...

Страница 10: ...2 00 01 61 88 0D 10 9C 41 00 01 7F 41 LEN 9 Transmission Query Source Master Dest Slave 13 Function Write Multiple Register 16 Func Desk Address 40001 Quantity 1 Byte count 2 Register values 00 01 Che...

Страница 11: ...elter 0 1 r h at 10 40 C 3 Shelter inaccuracy 4 r h dependant on v 2 m s and solar radiation 7 Technical data 16480 Weather Sensor u sonic WS7 Modbus Id No 00 16480 001130 Range of application 40 70 C...

Отзывы: