Lambrecht meteo WS6 Скачать руководство пользователя страница 11

Manual
Weather Sensor u[sonic]WS7 Modbus

(16480) u[sonic]WS7 Modbus

Manual

Subject to change without notice.

Trigger threshold: 

0.1 m/s

Trigger threshold: 

0.1 m/s 

Interface: RS-485

Protocols: 

Modbus RTU

Measuring rate: 

0.1...10 Hz

Supply voltage: 

6...60 VDC

 

heating : 24 VAC/DC ± 20 %

Current Consumption:  sensor: typ. 50 mA at 24 VDC

 

heating: max. 10 A at 24 VAC/DC

Heating data: 

60 W 

Dimensions: 

H 284 mm 

 Ø 199 mm 

 mast  adapter 

Ø 50 mm for mounting on standard pipe

Housing: 

seawater resistent aluminium

 

IP 66, IP 67

Weight: 

approx. 3.4 kg

Standards

•  Modbus RTU 

•  Standard of construction: VDE 0100 

•  Low voltage guide line: 72/23 EWG 

•  EMC/ EMI: DIN EN 60945 and DIN EN 61000-4-2, 3, 4, 6, 11

•  Salt fog: EN 60945

•  Protection class: DIN EN 60529

Accessories:

 

(please order separately)

32.14567.060010

 

Sensor cable, 15 m, 

 

4 pole M12 plug

Options: 

(please order separately)

36.09340.000000

 

Visualization and evaluation software

 

MeteoWare-CS3

 

(except for global radiation)

00.95800.010000

 

Data logger met[LOG]

00.14742.401002

 

Display unit METEO-LCD/IND

 

(except for global radiation)

1

 Temperature influence of the shelter: ac1.5 °C at v < 2 m/s 

and intensive solar radiation

2

 Temperature influence of the shelter: 

± < 0.1 % r.h. at +10…+40 °C

3

 Shelter inaccuracy: < 4 % r.h. dependant on v > 2 m/s and solar 

radiation 

Technical data

(16480) Weather Sensor u[sonic]WS7 Modbus
Id-No. 00.16480.001130

Range of application:  -40...+70 °C (heated: -50...+70 °C) • 

0...100 % r. h.

Parameters:

 

Wind direction

  Meas. principle:  ultrasonic

  Measuring range:  0...359.9°

  Accuracy: 

< 2° (>1 m/s) RMSE

 Resolution: 

0.1°

Wind speed

 

Meas. principle:  ultrasonic

  Measuring range:  0...65 m/s

  Accuracy: 

± 0.2 m/s RMSE (v < 10 m/s) •

   

± 2 % RMSE (10 m/s < v < 65 m/s)

  Resolution: 

0.1 m/s

Temperature 

 

  Meas. principle:  digital temperature sensor

  Measuring range:  -40...+70 °C

  Accuracy: 

± 0.1 K (0...60 °C) 

1) 

• 

   

± 0.2 K (-40...0 °C) 

1)

  Resolution: 

0.1 °C

Relative humidity

  Meas. principle:  capacitive, digital

  Measuring range:  0...100 % r. h.

  Accuracy: 

± 1.5 % (0...80 %) r. h. 

2)3)

   

± 2 % (>80 %) r. h.

  Resolution: 

0.1 % r. h.

Barometric pressure

  Meas. principle:  piezoresistive

  Measuring range:  300...1100 mbar

  Accuracy: 

± 0.5 mbar

  Resolution: 

0.1 mbar

Global radiation

  Meas. principle:  thermoelectric

  Measuring range:  0...2000 W/m² • Global radiation in the 

range of 285...3000 nm

  Accuracy: 

Second class

  Resolution: 

0.2 W/m²

Dew point temperature

  Meas. principle:  passive • calculated from air temperature 

and humidity

  Measuring range:  -40...+70 °C

  Resolution: 

0.1 °C

11

16480_WS7_b-de.indd    43.21

LAMBRECHT meteo GmbH 

 Tel 

+49-(0)551-4958-0

Friedländer Weg 65-67 

 Fax 

+49-(0)551-4958-312

37085 Göttingen 

 

 E-Mail  [email protected]

Germany 

 

 Internet  www.lambrecht.net

Содержание meteo WS6

Страница 1: ...n and display of the measured values using the MeteoWare CS evaluation software Easy space saving mounting on 50 mm standard pipe The Perfect Weather Sensor For industrial use as well as under extreme...

Страница 2: ...the appropriate disposal of waste electronic equipment Content 1 Introduction 3 1 1 Warranty 3 2 Setting to work 3 2 1 Installation conditions 3 2 1 1 Generally 3 2 2 Tools and installation aids 4 2...

Страница 3: ...ring elements This heating is particularly effective against ice and snow in all climatic zones The measuring principle allows very low starting values and high repeat accuracy The sensor rapidly can...

Страница 4: ...he two grup screws Finally the earth screw has to be connected to the ship s ground Acid free contact grease is recommended to protect contact surfaces against corrosion Note Follow all safety instruc...

Страница 5: ...t safety regulations for such works During the electrical installation and termination works the external circuit breaker must be switched off It is not permitted to open those housings by unauthorize...

Страница 6: ...ilization and communication of it s contents prohibited unless definitely permitted Infringement is bound to compensation All rights reserved for patent or registered pattern Ma e ohne Toleranzangabe...

Страница 7: ...r than a single byte that the most significant byte is sent first Example Big Endian Register size value 16 bits 0x1234 is transmitted in the sequence 0x12 0x34 To obtain the real measuring value divi...

Страница 8: ...10 1 Read only 30003 Wind speed maximum m s 10 1 Read only 30004 Wind speed minimum m s 10 1 Read only 30202 Wind direction average 10 1 Read only 30203 Wind direction maximum 10 1 Read only 30204 Wi...

Страница 9: ...n Read Input Register 4 Func Desk Byte count 2 Data 00 14 Checksum OK 3FB9 6 7 Descriptive sensor parameter registers Holding Register Register Parameter name Quantity of registers Remark Access type...

Страница 10: ...2 00 01 61 88 0D 10 9C 41 00 01 7F 41 LEN 9 Transmission Query Source Master Dest Slave 13 Function Write Multiple Register 16 Func Desk Address 40001 Quantity 1 Byte count 2 Register values 00 01 Che...

Страница 11: ...elter 0 1 r h at 10 40 C 3 Shelter inaccuracy 4 r h dependant on v 2 m s and solar radiation 7 Technical data 16480 Weather Sensor u sonic WS7 Modbus Id No 00 16480 001130 Range of application 40 70 C...

Отзывы: