Parameters menu
The card Service Menu is accessed by pressing the Info button (detail 11 - fig. 1) for 10 seconds. Press the Up/Down
buttons to select “tS”, “In”, “Hi” or “rE”. “tS” means Transparent Parameters Menu, “In” means Information Menu, “Hi”
means History Menu, “rE” means History Menu Reset. After selecting the menu, press the Info button to access it.
“ts” - Transparent parameters menu
Table. 4
Remote
Control
Card
Transparent Parameters
Range
Default
/
ECO 3,4 P N
ECO 5,5 P N
01
t01
Pellet loading function
0=Disabled
1=Enabled
0=Disabled
0=Disabled
02
t02
Delivery probe
0=Disabled
1=Enabled
1=Enabled
1=Enabled
03
t03
Fan setpoint in Lighting
0-200 Pa
51 Pa
51 Pa
04
t04
Auger activation time in Lighting
0-100
(1=4 seconds)
8 (32 seconds)
8 (32 seconds)
05
t05
Adjustment calculation timer (only with t18=1 and
t18=2)
0-100 seconds
5 seconds
5 seconds
06
t06
Ramp function timer
0-255 seconds
150 seconds
150 seconds
07
t07
Auger operation period (activation time + deactiva-
tion)
0-50 seconds
15 seconds
12 seconds
08
t08
Fan setpoint at Power 1
0-200 Pa
51 Pa
51 Pa
09
t09
Auger activation time at Power 1
0-100
(100=10 seconds)
28 (2.8 seconds)
38 (3.8 seconds)
10
t10
Fan setpoint at Power 2
0-200 Pa
74 Pa
70 Pa
11
t11
Auger activation time at Power 2
0-100
(100=10 seconds)
38 (3.8 seconds)
40 (4.0 seconds)
12
t12
Fan setpoint at Power 3
0-200 Pa
120 Pa
100 Pa
13
t13
Auger activation time at Power 3
0-100
(100=10 seconds)
46 (4.6 seconds)
45 (4.5 seconds)
14
t14
Fan setpoint at Power 4
0-200 Pa
150 Pa
120 Pa
15
t15
Auger activation time at Power 4
0-100
(100=10 seconds)
53 (5.3 seconds)
60 (6.0 seconds)
16
t16
Fan setpoint at Power 5
0-200 Pa
170 Pa
155 Pa
17
t17
Auger activation time at Power 5
0-100
(100=10 seconds)
56 (5.6 seconds)
65 (6.5 seconds)
18
t18
Burner operation selection (only with t02=1)
0=On/Off
1=Modulating
2=Modulating 2
0=On/Off
0=On/Off
19
t19
Post-ventilation 2 Time
0-255
(100=10 seconds)
200 (20 seconds)
200 (20 seconds)
20
t20
Photoresistance voltage (display only)
0-50 (50=5Vdc)
--
--
21
t21
Auger activation function in Lighting
0=Continuous
1=Cycle On/Off
0=Continuous
0=Continuous
22
t22
Photoresistance voltage threshold
0-100 (100=1Vdc)
50
50
23
t23
Burner type selection
1=P7/ECO 3.4 P
2=P12
3=ECO 5.5 P
1=P7/ECO 3.4 P
2=P12
24
P24
System water pressure protection selection
0=No Pressure switch,
1=Pressure switch
0=No Pressure
switch
0=No Pressure
switch
25
P25
Boiler type selection
1=Heating only
2=Storage with probe
3=Storage with probe
4=Instantaneous
1
1
26
P26
Heating pump activation temperature (P25=1)
0-80°C
30°C
30°C
Heating pump activation temperature (P25=2)
0-80°C
30°C
30°C
Heating pump activation temperature (P25=3)
0-80°C
30°C
30°C
Heating pump activation temperature (P25=4)
0-80°C
30°C
30°C
27
P27
Post-circulation
Heating pump
0-20 minutes
6 minutes
6 minutes
28
P28
Heating standby time
0-10 minutes
2 minutes
2 minutes