Press the Up/Down buttons to scroll the list of parameters in ascending or descending order. To change the value of a
parameter just press Enter at the parameter and then modify it with the Up/Down buttons: the change will be saved
automatically.
To return to the list of parameters just press Enter.
To return to the Service Menu just press the Info button. To exit the card Service Menu press the Info button for 10
seconds or exiting will be automatic after 15 minutes
29
P29
Pump operation
0=Post-Circulation
1=Continuous
0=Post-Circulation
0=Post-Circulation
30
P30
Pump deactivation temperature during Post-Circula-
tion (P25=1)
0-100°C
35°C
35°C
Pump deactivation temperature during Post-Circula-
tion (P25=2)
0-100°C
35°C
35°C
Pump deactivation temperature during Post-Circula-
tion (P25=3)
0-100°C
35°C
35°C
Pump deactivation temperature during Post-Circula-
tion (P25=4)
0-100°C
35°C
35°C
31
P31
Heating user max. set point
31-90°C
80°C
80°C
32
P32
No function (P25=1)
--
--
--
DHW pump activation temperature (P25=2)
0-80°C
40°C
40°C
DHW pump activation temperature (P25=3)
0-80°C
40°C
40°C
DHW pump activation temperature (P25=4)
0-80°C
40°C
40°C
33
P33
DHW pump Post-Circulation
0-20 minutes
4 minutes
4 minutes
34
P34
DHW standby time
0-20 minutes
4 minutes
4 minutes
35
P35
DHW user max. setpoint (P25=1)
--
--
--
DHW user max. setpoint (P25=2)
55-65°C
65°C
65°C
DHW user max. setpoint (P25=3)
55-65°C
65°C
65°C
DHW user max. setpoint (P25=4)
--
--
--
36
P36
No function (P25=1)
--
--
--
Hot water tank activation hysteresis temperature
(P25=2)
0-20°C
4°C
4°C
Hot water tank activation hysteresis temperature
(P25=3)
0-20°C
4°C
4°C
No function (P25=4)
--
--
--
37
P37
No function (P25=1)
--
-
--
Hot water tank preparation delivery temperature
(P25=2)
70-85°C
80°C
80°C
Hot water tank preparation delivery temperature
(P25=3)
70-85°C
80°C
80°C
DHW mode delivery adjustment temperature (P25=4) 50-75°C
55°C
55°C
38
P38
Boiler shell warm-up activation temperature (P25=1)
0-80°C
0°C
0°C
Boiler shell warm-up activation temperature (P25=2)
0-80°C
0°C
0°C
Boiler shell warm-up activation temperature (P25=3)
0-80°C
0°C
0°C
Comfort activation temperature (P25=4)
0-80°C
55°C
55°C
39
P39
Boiler shell warm-up deactivation hysteresis (P25=1) 0-20°C
5°C
5°C
Boiler shell warm-up deactivation hysteresis (P25=2) 0-20°C
5°C
5°C
Boiler shell warm-up deactivation hysteresis (P25=3) 0-20°C
5°C
5°C
Comfort deactivation hysteresis (P25=4)
0-20°C
20°C
20°C
40
P40
Safety and heating sensor selection
0-2
0
0
41
P41
Variable output relay operation (P25=1)
0-4
0
0
42
P42
No function (P25=1)
--
--
--
Legionella protection (P25=2)
0-7
0
0
Legionella protection (P25=3)
0-7
0
0
No function (P25=4)
--
--
--
Remote
Control
Card
Transparent Parameters
Range
Default
/
ECO 3,4 P N
ECO 5,5 P N