manualshive.com logo in svg
background image

HG78040E

INSTRUCTION MANUAL

FOR

CUP FLAME GAS BURNER

TYPE CB

YOKOI KIKAI KOSAKUSHO CO., LTD.

2720-1, OBORAGUCHI, NAKASHIDAMI
MORIYAMA-KU, NAGOYA 463, JAPAN

TEL: +81-52-736-0773

FAX: +81-52-736-0258

Содержание CB-1

Страница 1: ...HG78040E INSTRUCTION MANUAL FOR CUP FLAME GAS BURNER TYPE CB YOKOI KIKAI KOSAKUSHO CO LTD 2720 1 OBORAGUCHI NAKASHIDAMI MORIYAMA KU NAGOYA 463 JAPAN TEL 81 52 736 0773 FAX 81 52 736 0258 ...

Страница 2: ...1 Inspection of Product and Accessories and Outline and Specifications of Product 1 2 Installation 2 3 Piping 2 4 Operation 4 5 Inspection Nozzle Burner Tiles 5 6 Warning Plate 6 7 Troubleshooting 7 8 Structual Drawing 8 ...

Страница 3: ...ssories and Outline and Specifications of Product Inspection Check to confirm whether or not the product is exactly in accordance with your order by referring to the nameplate and the specification table given below Also check for damage and other irregularities caused by and during transportation Outline Perfect combustion on the burner tile surface allows proximate heating Heat emitted from the ...

Страница 4: ...e to prevent the burner tiles from dropping 2 In installing the burner to the furnace body fill up the clearance between the burner mount of the furnace and the burner tiles with refractory mortar and fix the burner to the furnace 3 Piping 1 Direct good care to the inside of the pipe not to leave seal tape fractions bond cutting chips etc there which may cause malfunction of the solenoid valve gov...

Страница 5: ...r other people may die or may be seriously injured In case of wrong operating it is predicted that dangerous situation will happen and the opertor or other people will be injured or only material described NOTE Even the matters classified to CAUTION have a possibility of causing serious results Then never fail to abide by matters discaribed Meaning of the mark Sample This is to tell that there is ...

Страница 6: ... i check the spark of it ELECTRIC SHOCK CAUTION Never fail to take off the site hole when igniting or firinf the burner flame in the furnace may blow out Never touch the mounting plate of the burner and fitting parts of the pilot burner These area are high temperature when the burner is burning TOUCHING PROHIBITED 1 Do not use the attached gasket for sering this burner 2 Put the replaced old gaske...

Страница 7: ...of the minimum combustion 0 1 0 5kPa by using the damper G Fully open the control damper and air purge the inside of the furnace Use approx 3 times as much as the furnace volume as the reference volume of air purge H Set the control damper to the position for the minimum combustion Igniting I Check to confirm that the cock solenoid valve and limiting valve located immediately before the burner hav...

Страница 8: ...P After setting the excess air ratio return the control damper to the position for the minimum combustion Q When the control motor is used joint the control damper to the specified position Extinguishing R Fully close the cock and solenoid valve located immediately before the burner and check to confirm that the fire has been extinguished Stop the combustion blower after the in furnace temperature...

Страница 9: ... monkey wrench to the gas nozzle 9 Inspect the inner surface of the burner tiles If the burner tiles are damaged as it may often affect combustion contact us for instructions 10 Reassemble the burner by reversing the order of the above steps Inspect and clean the burner and its accessories from time to time according to the operational conditions 7 Warning Plate When the installation construction ...

Страница 10: ...n NO Inspect the sequence the normal operation electric wire etc YES The burner nozzle YES Inspect the burner nozzle is clogged Before inspecting the burner and its peripheral Flame fails units carefully read the instruction manual attached to each equipment YES Inspect the following items A Are the ultravision frame rod and the protect relay are in normal operation B Is there a heavy fluctuation ...

Страница 11: ...tructual Drawing NO Parts Name Quan Note 1 Burner Tile 1 2 Burner Plate 1 3 Air Body 1 4 Gas Body 1 5 Air Nozzle 1 6 Gas Nozzle 1 7 Gas Pipe 1 8 Bolt M8 4 9 Bolt M6 4 10 Plug R 1 4 2 8 9 1 2 3 4 5 6 7 10 10 ...