background image

 8

CLEANING AND PREVENTIVE 
MAINTENANCE 

 

PRECAUTION AND CLEANING 
INSTRUCTIONS 

 

IMPORTANT

 : Before carrying out the 

cleaning and maintenance operations, 
disconnect the equipment from the mains 
power supply: 

 

 

-  

high temperatures can be reached inside 
the machine (90°C). After power supply has 
been removed, wait until the machine has 
reached the room temperature, before 
working on it. 

 

the machine protection degree is IP21, 
therefore it should not be washed with 
direct high pressure jets of water; 

 

never leave tools, parts or other loose 
material on or in the machine; 

 

BEFORE starting machine or cycle, after 
any maintenance or repair work, make sure 
all protective are correctly installed; 

 
 
 

DAY MAINTENANCE 

 
 

-   

Disconnect the machine with pushbutton 
"A"; 

Lift   the   overflow  pipe and let the water 

 

drain out of the tank; 

Wash thoroughly the   tank and  the filter 

 

housing to remove all impurities; 

Take the filters and clean it under running 

 

water; 

-  

Re-assemble the overflow   pipe   and the 

 

filters in their housings; 

Check and clean the washing and the 
rinsing jets; 

Clean the outer surface of the machine by 
using a wet sponge; don't use water jets 
because, beside being dangerous they 
could damage the electrical parts; don't 
use abrasive detergents; 

When the machine is to remain idle  for a 

 

long time, drain all  the water   from    the 

 

boiler   and    from   the   electropump. 

 

Also leave the    wash  tank  

open. 

 

NEVER WASH THE EXTERNAL PART  OF 
THE MACHINE WITH A WATER JET 
 
 

 

POSSIBLE TROUBLES - CAUSES - SOLUTIONS 

 

PROBLEMS 

CAUSES 

SOLUTIONS 

 
The machine doesn't catch 

Main switch is switched off; 

Turn ON the main switch; 

 
The water doesn't go in 

Water cock closed; 

Open water cock; 

 
 

The Overflow is not in  place; 

Reassemble the Overflow in   

 

 

place; 

 
Insufficient Washing 

Wrong detergent or dosage  

Use anti-foam detergent in the 

 

insufficient; 

right dosage and never with  

 

 

cold water; 

 
 

Low temperature in the tank; 

Wait untill the water gets hot; 

 
 

Dirt wash filter; 

Clean filter; 

 
Insufficient Rinsing 

Rinsing nozzles blocked; 

Unscrew and clean nozzles  

 

 

under running water; 

 
 

Hydraulic pressure lower than 

Wait till the pressure is on or buy 

 

1 bar - 100 kPa; 

a booster pump; 

 

CAUTION! FOR ANY OTHER TROUBLE, CALL SERVICE 

 

Содержание S280

Страница 1: ...achine Perfect washing up results as far as hygiene concerns and a correct operation of the dishwashing machine can be assured only in case the instructions reported in the present manual are carefull...

Страница 2: ...NOT attempt to move install set up or operate this machine until you have read and fully understood this Manual If doubt persists ask your supervisor never leave tools parts or other loose material o...

Страница 3: ...INSTRUCTIONS FOR THE USER INSTRUCTIONS POUR L UTILISATEUR...

Страница 4: ...5...

Страница 5: ...ust have the way to run on each part of the same C Turn the machine on by wall switch and push the switch A on the ON position The green lamp G becomes lighted and the machine loads automatically with...

Страница 6: ...ing agents in powder must be 1 5 2 5 g lt Mean concentration of liquid cleansing agents nust be 2 4 g lt In order to avoid scales and corrosions put cleansing agent above water level on the nearest ar...

Страница 7: ...n their housings Check and clean the washing and the rinsing jets Clean the outer surface of the machine by using a wet sponge don t use water jets because beside being dangerous they could damage the...

Страница 8: ...for the most suitable product which does not cause corrosion on the steel itself the onset of rust is most commonly caused by the use of unsuitable cleaning materials strongly acid chlorate based dete...

Страница 9: ...declines any responsibility in the case of interventions made by a non qualified personnel INSTRUCTIONS POUR L INSTALLATEUR Les instructions suivantes sont adress es un personnel qualifi qui est le se...

Страница 10: ......

Страница 11: ...st also be provided with a proper ground lead in accordance with the existings norms The electric cable must be of the following type H07RN F For the right choice of the cross section area refer to th...

Страница 12: ...2 and 12 5 French If the hardness values are higher than those mentioned above it is advisable to install a water softener WORK TEMPERATURES Water temperature 74 C Rinse temperature 82 90 C DO NOT TAM...

Страница 13: ......

Отзывы: