background image

16 

 

ENGLISH 

 

Second Section - FOR THE INSTALLER 

 

During installation, carry-out a good machine levelling, which is a prerequisite for a correct 
operation thereof. 

The Manufacturer cannot assume any responsability for any damage to persons or 
property deriving from the non-observance of the above-specified norms. 

For correct installation see draw page 18. 

 
 

ELECTRICAL CONNECTION 
 
Before connecting the machine, 
check to make sure the voltage 
outlet of the mains is  
the same as the voltage specified 
on the data plate of the machine.  
 

A main switch must be installed between 
the mains and the machine. This safety 
measure  
also requires that the minimum distance 
between the switch contacts is at least 3 
mm and the  
disconnection on all poles according to 

EN 

60204 (VDE 113)

 
Fuses on the main switch must be 

16 A

 . 

 
The mains must be wired to be able to 
handle the current drawn by the 
machine.The system must  
also be provided with a proper ground lead 
in accordance with the existings norms. 
The electric  
cable must be of the following  
type 

H07RN-F

 
For the right choice of the cross section 
area refer to the following table: 

 

   Cross Section area         Total loading  
 

mm²                               A 

 
 

0,75 

       < 6 

 

      6 ÷ 10 

 

1,5 

    10 ÷ 16 

 

 

2,5 

    16 ÷ 25 

 
 
 

The electrical safety of this equipment is 
only assured if it is connected as follows. 
 
It is necessary to connect the equipment to 
an effective ground installation, as 
specified by the  
electrical safety regulations in force. 
Chack that this basic requirement is 
complied with and, in case of doubt, ask for 
a careful check of  
the installation by a qualified personal. 
 
In addition, the equipment shall be part of 
an equipotential system, the effectiveness 
of which  
should be checked according to the 
regulations in force. 
 
The connection should be made at the 
screw marked by the respective label 
located on the  

equipment back side (

). 

 
 
THE MACHINE SHALL BE 
CONNECTED WITH AN EFFECTIVE 
GROUND CLAMP. 
 
The manufacturer declines any 
responsibility for any damages 
caused by lack of an effective  
ground installation. 
 
 
 
 
 

Содержание S280

Страница 1: ...achine Perfect washing up results as far as hygiene concerns and a correct operation of the dishwashing machine can be assured only in case the instructions reported in the present manual are carefull...

Страница 2: ...NOT attempt to move install set up or operate this machine until you have read and fully understood this Manual If doubt persists ask your supervisor never leave tools parts or other loose material o...

Страница 3: ...INSTRUCTIONS FOR THE USER INSTRUCTIONS POUR L UTILISATEUR...

Страница 4: ...5...

Страница 5: ...ust have the way to run on each part of the same C Turn the machine on by wall switch and push the switch A on the ON position The green lamp G becomes lighted and the machine loads automatically with...

Страница 6: ...ing agents in powder must be 1 5 2 5 g lt Mean concentration of liquid cleansing agents nust be 2 4 g lt In order to avoid scales and corrosions put cleansing agent above water level on the nearest ar...

Страница 7: ...n their housings Check and clean the washing and the rinsing jets Clean the outer surface of the machine by using a wet sponge don t use water jets because beside being dangerous they could damage the...

Страница 8: ...for the most suitable product which does not cause corrosion on the steel itself the onset of rust is most commonly caused by the use of unsuitable cleaning materials strongly acid chlorate based dete...

Страница 9: ...declines any responsibility in the case of interventions made by a non qualified personnel INSTRUCTIONS POUR L INSTALLATEUR Les instructions suivantes sont adress es un personnel qualifi qui est le se...

Страница 10: ......

Страница 11: ...st also be provided with a proper ground lead in accordance with the existings norms The electric cable must be of the following type H07RN F For the right choice of the cross section area refer to th...

Страница 12: ...2 and 12 5 French If the hardness values are higher than those mentioned above it is advisable to install a water softener WORK TEMPERATURES Water temperature 74 C Rinse temperature 82 90 C DO NOT TAM...

Страница 13: ......

Отзывы: