23
CLEANING AND PREVENTIVE
MAINTENANCE
PRECAUTION AND CLEANING
INSTRUCTIONS
-
IMPORTANT
: Before carrying out the
cleaning and maintenance operations,
disconnect the equipment from the mains
power supply.
-
High temperatures can be reached inside the
machine (90°C). After power supply has
been removed, wait until the machine has
reached room temperature, before working
on it.
-
The machine protection degree is IP21,
therefore it should not be washed with direct
high pressure jets of water.
-
never leave tools, parts or other loose
material on the machine or inside of it.
-
BEFORE starting machine or cycle, after
any maintenance or repair work, make sure
all protectives are correctly installed.
DAILY MAINTENANCE
-
Disconnect the machine with pushbutton
"A";
-
Lift the overflow pipe and let the water
drain out of the tank;
-
Wash thoroughly the tank and the filter
housings to remove all impurities;
-
Take the filters out and clean them under
running water;
-
Re-assemble the overflow pipe and the
filters in their housings;
-
Check and clean the washing and the
rinsing jets;
-
Clean the outer surface of the machine by
using a wet sponge; do not use water jets
because, besides being dangerous, they
could damage the electrical parts; do not
use abrasive detergents;
-
When the machine is to remain idle for a
long time, drain all the water from the
boiler and from the electropump.
Also leave the door open.
NEVER WASH THE EXTERNAL PART OF THE
MACHINE WITH A WATER JET
POSSIBLE TROUBLES - CAUSES - SOLUTIONS
PROBLEMS
CAUSES
SOLUTIONS
The machine doesn't catch
Main switch is switched off
Turn ON the main switch
The water doesn't go in
Water cock closed
Open water cock
The Overflow is not in place
Reassemble the Overflow in
place
Insufficient Washing
Wrong detergent or insufficient
dosage
Use anti-foam detergent in the
right dosage and never with
cold water
Low temperature in the tank
Wait until the water gets hot
Dirty wash filter
Clean filter
Insufficient Rinsing
Rinsing nozzles blocked
Unscrew and clean nozzles
under running water
Hydraulic pressure lower than
Wait until the pressure is on or
1 bar - 100 kPa
buy a booster pump
The lamp “D” is flashing slowly
Resins exhausted
Start regenerating of resins
(see page 20)
The lamp “D” is flashing
quickly
Salt exhausted
A
dd salt in the container
(see page 20)
CAUTION! FOR ANY OTHER TROUBLE, CALL SERVICE
Содержание 01FEKS
Страница 33: ......