![lamber 015-ek-plus Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/lamber/015-ek-plus/015-ek-plus_instruction-manual_671273031.webp)
DETERGENT REPLACEMENT AND CLEANING OF THE DETERGENT PUMP HOSES
Guidelines to be followed when replacing detergent :
- If you leave the machine without detergent, crystallization arises due to the formation of air bubbles
- Set up again detergent pump hose anytime you use a new detergent
- The whole system consists of a container, dosage hoses and detergent pump hoses and must be cleaned
before using a new detergent.
- Call on your authorized technical assistance to fulfil the necessary operations to obtain a good cleaning
result.
- You are recommended to proceed with the cleaning of the dosage hoses and the detergent pump with
water once a month.
Failure to comply with these guidelines will render this guarantee invalid. Lamber disclaims any
liability for consequential damage on the product.
You can clean yourself the dosage hoses and the detergent pump with water.
Guidelines:
A - Disconnect the suction hose from the
detergent can.
B - Connect the suction hose to a new
water recipient
.
C -
Switch
the Self-cleaning cycle
on (see
paragraph page 22)
D – Once self-cleaning is finished, connect
the suction hose to the detergent can
.
WARNING
: Respect security and chemical
dosage guidelines.
When using chemical products you must wear
personnal protection equipment, gloves and
protection glasses. Do not mix different
detergents together.
Attention !
Replace
every 6 months
the peristaltic pumps