Cable Assemblies
9.3.1
Power Supply and Ethernet Module
Figure 44: Power cable (left) and Ethernet (right) assembly components
9.3.2
Assembly Steps
The steps explained below cover the power cable assembly process in detail. The ethernet cable assembly is
very similar, however less complex, to work with. In general, place the Ethernet cord through each
component and mount to the enclosure. Tighten the Sealing Nut with a
Torque Force of 8 ~ 10 kgf.cm
. The
rest of the guide covers the power cord assembly.
Note:
To ensure the IP67 rating, the Ethernet cable diameter must be in the range of
4.5 mm
–
6.5 mm. If the cable is too small, there is a potential risk of environment factors
potentially damaging the internal hardware.
To assemble the power cable, follow these steps:
Insert the Ethernet cord through each component
–
sealing nut (i), clip (ii), sealing (iii), sealing body (iv),
gasket (v), and lock nut (vi) (
Figure 45
).
Figure 45: Insert Ethernet cord
Note:
To ensure the IP67 rating, the
cable diameter must be in the range of 5.5 mm
–
8.0 mm
. If
the cable is too small, there is a potential risk of environment factors potentially damaging
the internal hardware.