BTM410/411
Bluetooth
®
AT Data Module
35
www.lairdtech.com
Laird Technologies
AT COMMAND SET
REFERENCE
AT COMMAND SET
REFERENCE
Figure 3: SPP Example Device A - initiate connection, receiving data, command mode, disconnect
Figure 4: SPP example Device B - incoming connection, receiving data, disconnection
2.2 ATA {Accept Incoming SPP Connection Request}
Accept an incoming connection, which is indicated by the unsolicited string
<cr,lf>RING 123456789012<cr,lf> every second (123456789012 is the Bluetooth address of the
connecting device).
Response:
<cr,lf>CONNECT 123456789012,1101,<<cr,lf>
2.3 AT+SPD<bd_addr> {Make Outgoing SPP Connection}
Initiate an SPP connection to device with Bluetooth address <bd_addr> and SPP profile.
The timeout is specified by S register 505.
For backward compatibility, the following command fulfils the same purpose: ATD<bd_addr>.
Response:
<cr,lf>CONNECT 123456789012,1101,><cr,lf>
Or
<cr,lf>NO CARRIER<cr,lf>
Содержание BTM410
Страница 1: ...1 Version 3 0 ...