6.3.3 I/O
Analog In
Analog Input
It is designed to detect input voltage, which ranging between 0.00 and 3.30 volts.
Active:
The threshold of voltage value can be specified through a pull-down list.
• Disable
As default, it is set as Disable
• Alert High If input voltage value is higher than High Level setting, device will
send out an alert message to server to remind server an Alert High
event occurs.
• Alert Low If input voltage value is lower than Low Level setting, device will send
out an alert message to server to remind server an Alert Low event
occurs
• Alert High/Low
If input voltage is either higher than High Level or lower than Low
Level setting, device will send out alert message to server
High Level: Select threshold voltage value for Alert High
Low Level:
Select threshold voltage value for Alert Low
6.3.4 I/O
COM
RS232 COM PORT: Reserved by Laipac and not opened to user yet