INSTALL ELECTRIC POWER LINE
Figure 2-5. Recommended Electrical Layout
The characteristics of the electric power supply must match the power requirements specified
on the product identification plate.
The plate is located on the right side of the unit in the bottom left corner. Also refer to the
electrical schematic diagram that was shipped with the unit, included at the end of this
manual.
CONNECT ELECTRICAL LINE
Refer to the electrical schematic diagram and connect the electrical lines to the terminal block
inside the right side access panel as described below. Copies of the electrical schematic
diagrams are included at the end of this manual and a copy was shipped with the unit and also
stuck on the right side access panel (inside).
Remove the right side access panel by removing the screws that hold it in place. Save the
screws.
Refer to the electrical schematic diagram that was shipped with the unit.
Mechanically secure the flexible conduit to the electrical access hole.
The terminal block and ground connection are near the center of the side opening. Connect the
wires to the terminal block and ground connector accordingly.
The oven/steamer must be electrically grounded by the installer in accordance with the
National Electric Code, ANSI/NFPA No. 70-(latest edition), or the Canadian Electrical Code,
CSA C22.1.
If no further work inside the side panel is required at this time, such as plumbing and leak
checks, secure the right side access panel with the mounting screws.
47
90028771rev00
Oven/Steamer
Location Detailed
on
Dimension Drawing
Electrical Supply
CONNECTION
MAIN ELECTRIC
POWER SUPPLY
MAIN POWER SWITCH
AND FUSE BOX
7
-
1
-
2
-
3
-
4
-
5
-
6
-
Содержание Naboo Compact CBEN061
Страница 2: ... 2 90028771rev00 ...
Страница 20: ... 20 90028771rev00 INSTALLATION DIAGRAMS ...
Страница 64: ... 64 90028771rev00 ...
Страница 65: ... 65 90028771rev00 65 90028771rev00 ...
Страница 66: ... 66 90028771rev00 66 90028771rev00 ...
Страница 67: ......