Intr
oduction
Setup
Softwar
e
Maintenance
Spar
e Par
ts
Specifications
44
45
Specifications
Perf
orming
Sim
ulations
44
Overall Dimensions
SimMom:
Length / Width (manikin only): 69 in x 19 in (175.3 cm x 48.3 cm)
Width at Shoulders (manikin only): 19 in (48.3 cm)
Width at Hips (manikin only): 19 in (48.3 cm)
Weight (manikin only): 61.5 lbs (28 kg)
Shipping Dimensions:
Box 1 (Torso): 45m in x 26 in x 16 in, 73 lb (114.3 cm x 66 cm x
40.6 cm, 33.1 kg)
Box 2 (Legs & Accessories): 45 in x 26 in x 15 in, 49 lb (114.3 cm x
66 cm x 38.1cm, 22.2 kg)
Baby:
Length/ Width: 19 in x 6 in (48.3 cm x 15.2 cm)
Weight: 4.5 lbs (2.04 kg)
Manikin Power
External power:
Input voltage 9VDC, 1.5A
VitalSim battery:
6 C-cell batteries
Only use approved
SimMom
external power supply.
Air Pressure
External air connection: Max 16 psi
Temperature Limits
Operating temperatures: +4 ºC to 40 ºC (39 ºF to
104
ºF)
Storage temperatures:
-
15
ºC to 50 ºC (5 ºF to
122
ºF)
Environment - Manikin only
Relative humidity:
20% -90% (non-condensing)
DO NOT use outdoors in wet conditions.
Not tested with salt spray.
Materials Used in Manikin
Clothes:
Cotton,
Nylon
Skins and airways:
PVC
External hard plastics:
PVC, PC-ABS
Inner plastics:
Silicone, PVC,
ABS,
POM,
Nylon
Polyurethane,
Latex
(pneumothorax
bladders)
Metal components:
Aluminum, Brass, Steel
Caution Latex: This product contains Natural Rubber latex, which
may cause allergic reactions when in contact with humans.
Minimum Computer Requirements
•
Core 2 Duo or better
•
1 GB RAM (2 GB recommended)
•
1GB hard disk space,
•
1024x768, 1280x800, 1280x1024 or better
•
16bit color resolution or better
•
100% DPI required
•
Optical drive required for installation
Minimum Software Requirements
•
Windows XP or Windows 7
•
DotNet 3.5.1
Cleaning Fluids
To clean the manikin use only a
mild solution of liquid soap and
water
IV Fluids
Only use distilled or deionized water to simulate IV and IO
fluids.
Reservoir Capacities
Urine Reservoir: 400 mL
Blood Reservoir:
800 mL
Wig Size
Use a large wig.
Airway Adjustment Sizes
7.5 endotracheal tube
#4 LMA
Large Adult or Trainer Combitube,
KING LT – #4
Urine Catheter Sizes
12 French
Blood Pressure
Pressure range:
0-300 mmHg
Accuracy:
+/-4 mmHg
Calibration:
Pressure sensor must be calibrated to
sphygmomanometer.
Available pulses:
Carotid, brachial, and radial
Only two pulses can be palpatated at once.
Palpated BP:
Radial pulse turns off at systolic BP.
Brachial pulse turns off at 20 mmHg, to prevent
noise generation in auscultation area.
Adjust pulses to BP using the chart below:
Systolic BP
Carotid Pulse
Radial/Brachial Pulse
>= 88
Normal
Normal
< 88
Normal
Weak
< 80
Normal
Absent
< 70
Weak
Absent
< 60
Absent
Absent
Содержание SimMom
Страница 1: ...SimMom Directions for Use www laerdal com www limbsandthings com ...
Страница 2: ......
Страница 43: ...Introduction Setup Software Maintenance Spare Parts Specifications 43 Maintenance Performing Simulations ...
Страница 44: ...44 44 Notes ...
Страница 46: ...46 46 Notes ...
Страница 48: ...48 Notes 48 ...
Страница 49: ......
Страница 50: ... 2012 Laerdal Medical All rights reserved 20 05176 Rev B Printed in USA ...