Performing Simulations
Perf
orming
Sim
ulations
1. Remove the abdominal skin and ensure the PPH uterus is installed.
Lubricate the birth canal and inside of PPH uterus.
2. Lubricate placental fragment, and insert it into the uterus, ensuring
the pointed part of the fragment points towards the manikin’s
head.
3. Align the fragment’s round prominence with suction hole on
posterior wall of uterus (on the manikin’s right).
4. Lubricate the placenta, and introduce it into the uterus. It helps to
fold it in half in order to fit through the cervix.
5. Orient the placenta so that the round prominence sits snugly
into the corresponding cavity in the uterus (on the manikin’s left).
Ensure the fragment remains aligned with the placenta.
6. Fit the connector on vacuum pump hose to the quick fit connector
on one side of the back of the uterus.
7. Pump until dial reads -0.8-0.9 bar/-25 mmHg (approximately
8-10 strokes of pump).
8. Disconnect.
9. Repeat for second connector to secure placenta into back of
uterus.
10. Replace abdominal skin.
Boggy Uterus Bag Installation
1. Place the boggy uterus bag in position on PPH uterus. The
concave surface of bag aligns with the convex surface of uterus.
2. Place support foam under the uterus and feed the air supply tube
(green luer connector) through the right cutout of the foam. The
support foam prevents the uterus from flopping back when
palpating through the abdomen.
Содержание SimMom
Страница 1: ...SimMom Directions for Use www laerdal com www limbsandthings com ...
Страница 2: ......
Страница 43: ...Introduction Setup Software Maintenance Spare Parts Specifications 43 Maintenance Performing Simulations ...
Страница 44: ...44 44 Notes ...
Страница 46: ...46 46 Notes ...
Страница 48: ...48 Notes 48 ...
Страница 49: ......
Страница 50: ... 2012 Laerdal Medical All rights reserved 20 05176 Rev B Printed in USA ...