background image

6

Thermostat cartridge

The thermostat cartridge is available as a spare part, and 
may need to be replaced more often if it is regularly exposed 
to temperatures close to, or above, boiling point.

The number is engraved on the cartridge.

No. Opening 

temperature

5839 63°C

8719  

72°C   

1456  

78°C

1467 83°C

Service

Before carrying out any servicing work, close the three shut-
offs by turning the lever on the valves at right angles to the 
direction of the pipe. This makes it easy to access the pump, 
thermal valve and check valve for service.

If operating interruptions still occur, even though the 
system has been bled, there may be dirt such as lint, tape or 
thread swarf stuck in the coupling. Disassemble and clean. 
Clean all sealing surfaces when reassembling:

1. The thermal valve 

2. The self-circulation valve

3. The pump impeller

In some installations, there are problems with extremely 
high levels of contaminants. These can form deposits inside 
the pump, which may result in stoppages. 

Instructions for replacing the 
thermostat in Laddomat 21-60

Check that the pump is switched off. 

Close the three shut-offs. 

Unscrew the cover opposite the pump.

Remove the cover with the spring, plunger and thermostat 
from Laddomat 21-60. 

The thermostat is held in place on the plunger by an O-
ring. Detach the thermostat from the plunger carefully 
using a screwdriver (see image on right). 

Push the new thermostat into the plunger. 

Reinstall the cover with the spring, plunger and thermostat. 
Open the shut-off valves.

Wait a few minutes before starting the pump to allow any 
air to rise and escape from the system. 

The installation is now ready for use.

Blocking the check valve

If you, for some reason, want to completely shut off the self 
circulation function, the check valve must be blocked.
Use the blocking clip, placed at the bottom of the EPP-
insulation (Picture 3), to block the check valve. 
The clip is then fastened around the check valve axis ac-
cording to picture 5.
To reach the axis, the spring needs to be removed.

Picture 2

Picture 1

Picture 4

Picture 5

Picture 3

The blocking clip is 
mounted here.

Blocking 
clip

Содержание 21-60

Страница 1: ... event of electrical power failure stopping the pump transfer the heat in the boiler to the tank through self circulation Operation Laddomat 21 60 functions fully automatically provided that pump start and stop is automated See page 3 The settings described in this User manual are normally made only once The Laddomat requires no special supervision or service Technical data Pump Laddomat LM6 stand...

Страница 2: ...2 Description of functions Operating phase Start up Final phase Self circulation Connection to bottom of boiler Connection to bottom of tank Connection to top of boiler ...

Страница 3: ... delivery temperature The lower the return temperature the longer the heat in the tank lasts Dimensioning Generous pipe dimensions and short lengths guarantee operating reliability even when the demand for heat is high This also allows effective self circulation in the event of power failure Recommended pipe dimensions at a maximum boiler to tank distance of 2 m Total length would then be 2 2 m 6 ...

Страница 4: ...ch the boiler before the other tanks are completely filled Tank 2 will be virtually unused If the system is connected incorrectly the warm water and the heat will run out earlier than estimated after the burner has stopped since tank 1 will cool down more quickly than the other If these requirements cannot be met there are other connection options Equal pipe lengths To achieve equal resistance it ...

Страница 5: ...5 NOTE See information on page 3 about the expansion vessel Connection suggestions Bottom connection of the expansion vessel gives reduced heat losses Alternative installation with open expansion vessel ...

Страница 6: ...mp which may result in stoppages Instructions for replacing the thermostat in Laddomat 21 60 Check that the pump is switched off Close the three shut offs Unscrew the cover opposite the pump Remove the cover with the spring plunger and thermostat from Laddomat 21 60 The thermostat is held in place on the plunger by an O ring Detach the thermostat from the plunger carefully using a screwdriver see ...

Отзывы: