17
This sign recommends a qualified
professional to perform this operation
3.16. Troubleshooting
Problem
Possible cause
Action
The fire does not burn well
The fire does not last
Green or wet wood
Use hard wood, with at least 2 years of cut and
stored in a ventilated and sheltered place.
Logs are too big
To light the cooker use newspaper and kindling
wood or firelighters. Once established, used
smaller logs of a similar size.
Bad quality wood
Use hard wood that produces heat and embers
(chestnut, ash, maple, birch, elm, beech, oak,
etc.)
Direct draught rod
Check that the direct draught rod is open
Not enough primary air
Open the primary air control completely, or even
open the door a little bit.
Not enough draft
X
Check the flue is not blocked. Remove any soot
from the flue air ways.
Check the flue outlet has not become damaged
The fire has too much flame
Excess of primary air
Close all or part of the primary air inlet and the
draught check valve.
Excessive draft
X
Install a draft regulator
Expulsion of smoke into room
Bad quality wood
Do not burn continuously, chips, carpentry
remnants (plywood, pallets, etc.)
Cold flue
Reheat the flue as quickly as possible using
newspaper and kindling to instant heat
Smoke entering room during
burning
The room is depressed
In facilities equipped with VMC, half open a
window until the fire is well lit.
Not enough draft
X
Check the status of the duct vent and isolation
duct.
Verify that this is not obstructed, make a
mechanical cleaning if necessary.
Downdraft
X
Install an anti-down draft cowl to the top of the
chimney rendering at the top of the chimney
Insufficient Heat Output
The room is in depression
X
In rooms equipped with VMC, it is necessary to
have an air intake from outside
Bad quality wood
Only use recommended fuel
Bad convection air combination
Check the convection circuit (air input grids,
spreading grid) Verify that the adjoining rooms
are equipped with ventilation grids to enhance
hot air spreading.
Water condenses (after the
cooker has been lit more than 3
or 4 times)
Green or wet wood
Use hard wood, with at least 2 years of cut and
stored in a ventilated and sheltered place.
Not enough draft
Check the condition of the flue and insulation.
Check that the piping is not blocked. Clean
mechanically if necessary
Circulation pump start point not set
properly
If not already fitted, fit a contact thermostat. Use
it to set the pump start-stop point better.
Содержание Vulcano 7T E3 E/E
Страница 1: ...INSTRUCTIONS BOOK Vulcano 7T E3 E E Cookers...
Страница 23: ...22 6 EXPLODED DIAGRAM VULCANO 7 E3 E E GENERAL EXPLODED DIAGRAM...
Страница 24: ...23 A VULCANO 7 E3 E E COOKER FRAME SUB COMPONENTS EXPLODED DIAGRAM...
Страница 25: ...24 B VULCANO 7 E3 E E FIREBOX DOOR SUBCOMPONENTS C VULCANO 7 E3 E E OVEN DOOR SUB COMPONENTS EXPLODED DIAGRAM...
Страница 28: ...27 H VULCANO 7 E3 E E UNDERNEATH OVEN DRAWER SUB COMPONENTS EXPLODED DIAGRAM...