background image

 

 

INSTRUCTIONS FOR THE INSTALLER 

11 

 

 

2.  

If  we  are  careful  not  to  bend  the  tabs 

more  than  45º,  we  can  extract  the  frame, 
even once the apparatus is embedded. 

 

Figure No.13 -

 

Close up of the bent tab 

In 

any 

case, 

Lacunza 

always 

recommends  adhering  the  frame  to  the 
wall  by  its  4  sides  using  high-temperature 
silicon. The  frame  is  flexible  and therefore 
it  can  be  adapted  to  any  imperfections on 
the wall. 

2.3.9.

 

Turbine-potentiometer connection  

These are the connection instructions in 

order to control the ventilator system using 
the supplied potentiometer: 

 

Figure No.14 -

 

Connections to be carried 

out in the potentiometer 

WARNING:  the  operating  temperature 

of the potentiometer supplied by Lacunza 

is  from  0  to  40ºC.  Particular  care  should 
be  taken  when  choosing  where  it  will  be 
positioned  so  that  it  is  not  damaged  by 
temperatures  above  40ºC.  Insulate  the 
potentiometer correctly so as to avoid this 
problem. 

Read  the  potentiometer  instruction 

manual. 

Due to the movement of the ventilators, 

this apparatus may vibrate structures that 

come into contact with it. These vibrations 

may cause noise. To prevent these 

vibrations from occurring, a damping 

element that is also resistant to high 

temperatures (up to 200ºC) should be 

positioned between the base of the 

apparatus and the supporting structure. 

2.4.

 

Chimney flue 

The  chimney  flue  must  comply  with 

present  standards  on  the  installation  of 
chimneys. 

In  rooms  equipped  with  Controlled 

Mechanical  Ventilation,  the  ventilation 
outlet  must  never  be  connected  to  the 
flue. 

The appliance must always have its own 

chimney flue, never sharing a chimney flue 
with another appliance. 

2.4.1.

 

Type of flue 

The  flue  must  be  made  of  special 

material designed to resist the products of 
combustion (e.g. stainless steel, enamelled 
steel, etc.). 

Non-central-heating 

appliances 

(without  back  boiler)  require  an  insulated, 
double-sleeve  flue  only  on  those  sections 
that  run  outdoors  or  through  cold  areas. 
Single  piping  can  be  used  inside  the 
building,  the  heat  of  the  gases  serving  to 
heat  rooms,  insulating  only  those  sections 
where  excess  temperature  may  cause 
damage.  

Содержание IV-800

Страница 1: ...IV 800 Instruction Book...

Страница 2: ...Warning to installers 5 2 2 Room for installation 5 2 2 1 Ventilation of the room 5 2 2 2 Location of the appliance in the room 6 2 3 Installation of the appliance 6 2 3 1 Floor 6 2 3 2 Safety distan...

Страница 3: ...4 1 1 Firebox 20 4 1 2 Flue socket 20 4 1 3 Painted sheet steel cast iron parts 20 4 1 4 Firebox glass 20 4 1 5 Electrical system 20 4 1 6 Air intake registers 20 4 2 Maintenance of the chimney flue 2...

Страница 4: ...legislation applicable in each country and this instruction book 1 1 General characteristics Unit IV 800 Nominal Heat Output N H O to atmosphere kW 8 5 Efficiency at N H O 78 CO emission at 13 O2 at N...

Страница 5: ...dity of the fuel fuel loads fuel load frequencies flue draught and system of installation indicated in this Instruction Book Failure to respect these conditions may lead to problems with the appliance...

Страница 6: ...lutely crucial to ensure the suitable renewal of the air in the room in which the appliance is fitted the room must always have at least two permanent grilles or openings to the exterior in order to r...

Страница 7: ...the left hand side 400 From the rear 400 From the front 1000 Bear in mind that it may even be necessary to protect non combustible material in order to prevent breakage deformation etc as a result of...

Страница 8: ...ow the appliance can be encased properly Figure No 5 Interior diagram of the casing Key to casing diagram 1 Ceiling 2 Flue 3 Incombustible material Inner hood insulation 4 Insulating deflector made of...

Страница 9: ...it the necessary inspection accesses trap doors hatches etc so that everything inside the hood that may need maintenance work or replacement can be accessed at any time e g counterweight system hydrau...

Страница 10: ...e appliance working at Nominal Heat Output Output kW IV 800 2 5 Note The values shown in the above table were measured at the appliance output point and based on tests performed at nominal heat output...

Страница 11: ...n be used to attach it to the apparatus This should be done as follows Loosen without removing the two screws on the upper support of the door with a 10 mm wrench By lifting this piece up the door can...

Страница 12: ...al Due to the movement of the ventilators this apparatus may vibrate structures that come into contact with it These vibrations may cause noise To prevent these vibrations from occurring a damping ele...

Страница 13: ...imum Each 45 bend is equivalent to a 0 5m reduction in flue length Horizontal flue sections should not be installed because they cut updraught a great deal If the flue draws at more than 20Pa then an...

Страница 14: ...acle located within a 10m radius of the chimney outlet by more than 1m Figure No 16 Distances between the chimney crown and objects within a 10m radius The chimney crown must clear any neighbouring bu...

Страница 15: ...ly chopped wood produces greater heat output but also burns more quickly Optimum fuels Beech Other fuels Oak chestnut ash maple birch elm etc Pine and eucalyptus logs are low density and produce very...

Страница 16: ...rm weather warm days early hours of the afternoon on sunny days may lead to lighting and updraught problems Certain weather conditions such as fog ice humidity entering the flue etc may hinder suffici...

Страница 17: ...nutes Always load with the nominal amount see table in section 1 1 For minimum burning e g at night use thicker logs When the firebox is loaded close the door Be careful when placing logs in the fireb...

Страница 18: ...e released hatch position In order to fill the complete capacity of the ashpit box shake it back and forth Remove the separator This way there is even greater access to push the ashes from the firebox...

Страница 19: ...cooking grille is an element to be used intermittently The grille is not designed to work non stop over the fire Never close the door with the handles inside the firebox These handles should only be u...

Страница 20: ...e mains electricity supply in accordance with the conditions described in the relevant section in 1 1 Potentiometer operation By means of its rotating lever the potentiometer controls the flow of hot...

Страница 21: ...for longer However the glass may get dirty the longer the appliance is used Special degreasing products designed for the purpose should be used to clean it Clean when the glass is cold and taking car...

Страница 22: ...ebox block the connection hole with damp cloths and call the fire brigade 4 3 Important advice Lacunza recommends that only Lacunza authorised replacement parts be used Lacunza accepts no liability fo...

Страница 23: ...ips carpentry scraps plywood pallets etc Cold flue Heat up the flue by burning a piece of paper in the firebox Smoke during burning The room is at low pressure In rooms with Controlled Mechanical Vent...

Страница 24: ...ndici n IF 800 1 9 5044400000 IV 800 Deflector vermiculita IZQ DCHO 2 10 5044400001 IV 800 Angulo sujeci n deflector 1 11 504420000011 Pieza m vil registro primario IF 800 1 12 504420000012 Pieza m vi...

Страница 25: ...DECLARATION OF PERFORMANCE 24 7 DECLARATION OF PERFORMANCE...

Страница 26: ...DECLARATION OF PERFORMANCE 25 7...

Страница 27: ...CE MARK 26 8 CE MARK...

Страница 28: ...LACUNZA KALOR GROUP S A L Pol Ind Ibarrea s n 31800 Alsasua Navarra Spain Tel 00 34 948 56 35 11 Fax 00 34 948 56 35 05 e mail comercial lacunza net Website www lacunza net EDITION 0...

Отзывы: