background image

 

 

INSTRUCTIONS FOR THE INSTALLER 

 

 

2.  

2.2.2.

 

Location of the appliance in the 

room 

Choose  a  location  in  the  room  which 

favours  good  hot-air  distribution  by 
convection and radiation. 

The 

interior 

of 

the 

apparatus 

incorporates  two  handles  which  facilitate 
its transferral to its final location.  Hold the 
apparatus  on  both  sides,  as  displayed  in 
the image: 

 

Figure No.3 -

 

Positioning the handles for 

transferral  

2.3.

 

Installation of the appliance 

2.3.1.

 

Floor 

Make sure  that the base  can withstand 

the  total  constructed  weight  of  the 
appliance and its casing. 

The apparatus should not be  placed on 

combustible material. 

2.3.2.

 

Safety distances 

Be  sure  to  respect  the  appliance 

installation  distances  from 

combustible 

materials

.  Looking  at  the  appliance  head-

on:

 

 

Distance to 

combustible  

materials 

(mm)  

From the right-hand side 

400 

From the left-hand side 

400 

From the rear 

400 

From the front 

1000 

Bear  in  mind  that  it  may  even  be 

necessary  to  protect  non-combustible 
material  in  order  to  prevent  breakage, 
deformation,  etc.,  as  a  result  of 
overheating 

if 

the 

non-combustible 

material is not  designed to withstand high 
temperatures.  

2.3.3.

 

Checks before lighting for the first 

time 

 

Make  sure  that  the  glass/es  is/are 

not broken or damaged. 

 

Make  sure  that  the  flueway  is  not 

obstructed with packing or loose parts. 

 

Check  the  deflectors  are  correctly 

positioned. 

 

Make  sure  that  the  airtight  joints 

on  the  flue  circuit  are  in  perfect 
condition. 

 

Make  sure  that  the  doors  close 

properly. 

 

Make sure that all moving parts are 

fitted in place. 

2.3.4.

 

Height adjustment and levelling the 

appliance 

The apparatus incorporates 4 adjustable 

legs for its levelling and height  adjustment 
with a 24 mm wrench. 

 

Figure No.4 -

 

Close up of the 24 mm 

wrench for adjusting the legs 

If a fitting height of below 535 mm is 

required, the 4 legs can be removed by 

unscrewing them completely. 

Содержание IV-800

Страница 1: ...IV 800 Instruction Book...

Страница 2: ...Warning to installers 5 2 2 Room for installation 5 2 2 1 Ventilation of the room 5 2 2 2 Location of the appliance in the room 6 2 3 Installation of the appliance 6 2 3 1 Floor 6 2 3 2 Safety distan...

Страница 3: ...4 1 1 Firebox 20 4 1 2 Flue socket 20 4 1 3 Painted sheet steel cast iron parts 20 4 1 4 Firebox glass 20 4 1 5 Electrical system 20 4 1 6 Air intake registers 20 4 2 Maintenance of the chimney flue 2...

Страница 4: ...legislation applicable in each country and this instruction book 1 1 General characteristics Unit IV 800 Nominal Heat Output N H O to atmosphere kW 8 5 Efficiency at N H O 78 CO emission at 13 O2 at N...

Страница 5: ...dity of the fuel fuel loads fuel load frequencies flue draught and system of installation indicated in this Instruction Book Failure to respect these conditions may lead to problems with the appliance...

Страница 6: ...lutely crucial to ensure the suitable renewal of the air in the room in which the appliance is fitted the room must always have at least two permanent grilles or openings to the exterior in order to r...

Страница 7: ...the left hand side 400 From the rear 400 From the front 1000 Bear in mind that it may even be necessary to protect non combustible material in order to prevent breakage deformation etc as a result of...

Страница 8: ...ow the appliance can be encased properly Figure No 5 Interior diagram of the casing Key to casing diagram 1 Ceiling 2 Flue 3 Incombustible material Inner hood insulation 4 Insulating deflector made of...

Страница 9: ...it the necessary inspection accesses trap doors hatches etc so that everything inside the hood that may need maintenance work or replacement can be accessed at any time e g counterweight system hydrau...

Страница 10: ...e appliance working at Nominal Heat Output Output kW IV 800 2 5 Note The values shown in the above table were measured at the appliance output point and based on tests performed at nominal heat output...

Страница 11: ...n be used to attach it to the apparatus This should be done as follows Loosen without removing the two screws on the upper support of the door with a 10 mm wrench By lifting this piece up the door can...

Страница 12: ...al Due to the movement of the ventilators this apparatus may vibrate structures that come into contact with it These vibrations may cause noise To prevent these vibrations from occurring a damping ele...

Страница 13: ...imum Each 45 bend is equivalent to a 0 5m reduction in flue length Horizontal flue sections should not be installed because they cut updraught a great deal If the flue draws at more than 20Pa then an...

Страница 14: ...acle located within a 10m radius of the chimney outlet by more than 1m Figure No 16 Distances between the chimney crown and objects within a 10m radius The chimney crown must clear any neighbouring bu...

Страница 15: ...ly chopped wood produces greater heat output but also burns more quickly Optimum fuels Beech Other fuels Oak chestnut ash maple birch elm etc Pine and eucalyptus logs are low density and produce very...

Страница 16: ...rm weather warm days early hours of the afternoon on sunny days may lead to lighting and updraught problems Certain weather conditions such as fog ice humidity entering the flue etc may hinder suffici...

Страница 17: ...nutes Always load with the nominal amount see table in section 1 1 For minimum burning e g at night use thicker logs When the firebox is loaded close the door Be careful when placing logs in the fireb...

Страница 18: ...e released hatch position In order to fill the complete capacity of the ashpit box shake it back and forth Remove the separator This way there is even greater access to push the ashes from the firebox...

Страница 19: ...cooking grille is an element to be used intermittently The grille is not designed to work non stop over the fire Never close the door with the handles inside the firebox These handles should only be u...

Страница 20: ...e mains electricity supply in accordance with the conditions described in the relevant section in 1 1 Potentiometer operation By means of its rotating lever the potentiometer controls the flow of hot...

Страница 21: ...for longer However the glass may get dirty the longer the appliance is used Special degreasing products designed for the purpose should be used to clean it Clean when the glass is cold and taking car...

Страница 22: ...ebox block the connection hole with damp cloths and call the fire brigade 4 3 Important advice Lacunza recommends that only Lacunza authorised replacement parts be used Lacunza accepts no liability fo...

Страница 23: ...ips carpentry scraps plywood pallets etc Cold flue Heat up the flue by burning a piece of paper in the firebox Smoke during burning The room is at low pressure In rooms with Controlled Mechanical Vent...

Страница 24: ...ndici n IF 800 1 9 5044400000 IV 800 Deflector vermiculita IZQ DCHO 2 10 5044400001 IV 800 Angulo sujeci n deflector 1 11 504420000011 Pieza m vil registro primario IF 800 1 12 504420000012 Pieza m vi...

Страница 25: ...DECLARATION OF PERFORMANCE 24 7 DECLARATION OF PERFORMANCE...

Страница 26: ...DECLARATION OF PERFORMANCE 25 7...

Страница 27: ...CE MARK 26 8 CE MARK...

Страница 28: ...LACUNZA KALOR GROUP S A L Pol Ind Ibarrea s n 31800 Alsasua Navarra Spain Tel 00 34 948 56 35 11 Fax 00 34 948 56 35 05 e mail comercial lacunza net Website www lacunza net EDITION 0...

Отзывы: