English
24 EN
19. Defects - Malfunctions
Direct action by the customer
Before calling service personnel, to avoid useless expense, check whether the machine problem corresponds to one of
the cases listed below.
PROBLEM
The coffee machine does not work and
the display (
Ts
) is blank.
/HDNLQJIURPWKH¿OWHUKROGHUULP
11
).
Coffee dispensing time too short.
Coffee drips out of machine.
Loss of water under the machine.
Machine heated up, but it does not
dispense coffee.
The automatic level control devices
remain in operation.
SOLUTION
Check the electricity supply.
&KHFN WKH SRVLWLRQ RI WKH 212))
switch (
1
).
Clean using the special brush provided.
8VHD¿QHUJULQG
Use new coffee.
Clean.
Use a coarser grind.
Clean.
Clean.
Open.
Wait until water is available or call a
plumber.
Same solution as above.
CAUSE
No electricity supply.
Underpan gasket dirty with coffee.
C o f f e e g r o u n d t o o c o a r s e .
Coffee too old.
)LOWHUKROHVEORFNHGRU¿OWHUKROGHU
11
)
outlet hole dirty.
&RIIHHJURXQGWRR¿QH
D i s c h a r g e w e l l c l o g g e d u p .
Discharge pan hole blocked.
Water supply or water softener tap
closed. No water in system.
Same causes as above.