LaCie 2big Network 2
• DESIGN BY NEIL POULTON
Introduction
User Manual
page 11
1.4.3. LED Behavior
The front and rear LED indicate drive status and activity. This section describes the behavior of the LED indicators.
TECHNICAL NOTE:
Even if you have turned off the front LED using the Dashboard (
4.12. Dashboard: Eco Management
), events triggering a red
light will always cause the front LED to turn on.
Front LED Color
Rear LED Color
2big Network 2 State
Blinking blue
Activity LED for working disk(s)
(until they are fully initialized)
Occurs as the 2big is booting; will cease once the drives are fully initial-
ized
RAID synchronizing; will cease once operation has concluded
Solid blue
Activity LED for working disk(s)
Drive working (read/write)
Blinking blue/red
Activity LED for working disk(s)
RAID is degraded; data is intact but no longer protected from further failed
disks
Solid red in non-functional disk(s)
Blinking red
Activity LED for working disk(s)
Power supply has been cut but power is still being supplied through the
UPS
Temperature alert (first level)
Solid red
Activity LED for working disk(s)
Temperature alert (critic level) – the product will shut off
Activity LED for working disk(s)
Power supply has been cut and the UPS has run out of reserve power – the
product will shut off
Solid red in non-functional disk(s)
RAID has failed and data has been lost