SERVICE INSTRUCTIONS:
- Lubricating gas valve.
If the gas taps tends to stick slightly, you may follow this procedure:
1 - Shut off the valve and / or the main electrical supply of the unit.
2 - Take out the knob corresponding to the gas valve to be greased.
3 - Unscrew the head from the body of the burner valve.
4 - Grease the tap shaft (High temperature lubricant, for example: SILICAL GEL ™ BARBAHL).
Caution! Any excess grease should be removed.
Reverse operation 3 to 1 (in that order) to put valve and knob back on.
- LIMITING THERMOSTAT:
To access internal components. Lift and secure top.
Press pushbutton item
U
(Figure 40) in order to reset the
limiting thermostat.
Note:
ALWAYS IDENTIFY
the reason why the thermostat
tripped.
Figure 38
Fig. 40
U