![Lacanche Fontenay Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/lacanche/fontenay/fontenay_manual_668287013.webp)
INSTALLER’S MANUAL
CHAMBERTIN – CHASSAGNE - FONTENAY
Page 13 of 47 – US –
Remove the pan supports and burners. Unscrew the screw(s)
C
on burner UF or T
(Figures 13 and 14). Pull and raise the top after having loosened the 2 screws
D
(Fig. 15), wedge the cooking surface.
A pressure regulator (fig. 16) is located in the right rear corner under the hob, to
gain access to the pressure regulator, remove the top.
The reversible cap is labelled either «LP» or «Nat» and is easily recognized by the raised center screw slot (for
Natural) or the center depth (for LP).
To change LP to Natural or vice versa, the seal screw in the regulator lid is unscrewed, reversed and reinstalled to
convert from one setting to another (Figures 17 and 18).
Fig. 15
D
Convertible regulator
Figure 13
C
Figure 14
C
C
LP Setting
Fig. 18
Fig. 16
Fig. 17
NAT Setting
Содержание Fontenay
Страница 2: ...Page 2 of 47 US ...
Страница 8: ...Page 8 of 47 US ...
Страница 10: ...Page 10 of 47 US ...
Страница 20: ...INSTALLER S MANUAL CHAMBERTIN CHASSAGNE FONTENAY Page 20 of 47 US ...
Страница 28: ...Page 28 of 47 US ...
Страница 30: ...Page 30 of 47 US ...
Страница 32: ...Page 32 of 47 US ...
Страница 45: ...USER S MANUAL CHAMBERTIN CHASSAGNE FONTENAY Page 45 of 47 US ...