INSTALLER’S MANUAL
Recommendations :
Ensure that the oven is set to the type of gas used (see label on the gas connector).
,IWKHJDVVXSSO\LVQRWFRPSDWLEOHZLWKWKHJDVVHWWLQJRI\RXUUDQJHWKHVHWWLQJPXVWEHPRGL¿HG5HIHU
to the “Changing gas type” section of the present instructions.
Butane-fuelled units
: Connect unit to 2.6 kg/h pressure reducer. Use two cylinders connected to a 3-way
valve ahead of the pressure regulator in case of prolonged, continuous duty.
Propane-fuelled units
: Connect unit to a 3.0 kg/h pressure reducer. Use two cylinders and a 3-way
valve ahead of the pressure regulator in case of prolonged, continuous duty. The use of 37 kg or external
cryogenic tanks is both possible and recommended.
Before connection :
Check
:
¸
That the gas supply pressure matches the gas pressure for which the range is set.
¸3LSHZRUNLVSHUIHFWO\FOHDQLQRUGHUWRSUHYHQWWKHLQMHFWRUVEHFRPLQJEORFNHGDQGPDOIXQFWLRQLQJRI
the magnetic heads.
¸7KHJDVIRUZKLFKWKHDSSOLDQFHZDVVHWXSUDWLQJSODWHDQGPDUNLQJV
¸&URVVVHFWLRQDODUHDRIJDVVXSSO\SLSHZRUNLVFRPSDWLEOHZLWKWKHDSSOLDQFH¶VWKHUPDORXWSXW
¸&RUUHFWIUHVKDLUIORZUDWHDLUVXSSO\VXI¿FLHQWWRHQDEOHFRUUHFWFRPEXVWLRQWRRFFXU
(see appendix 1).
Gas connection :
Male coupling Ø 15/21, 1/2” gas thread on ( see
A
/ figure
1
).
After connection :
Check the mains pressure at (see
B
/ figure
2
).
Check your connection is gastight.
B
A
1
2
GAS CONNECTION
Cormatin - Ft 120a - GB - Rév 07 - Modifié le : 07/10/2013 13/44