INSTALLER’S MANUAL
CHANGING GAS TYPE (Changing the Jets on a Gas Cooker)
HOB :
Ź
Lift the air ring up to reveal the injector (see
A
, figure
1
).
Ź
Replace the injectors (see
B
, figure
1
) in accordance with table
5
in appendix
0
( Ø in 1/100
mm).
If necessary, the mixer tubes of the lateral burners maintained by a cross-bar (see
C
, figure
2
),
may be released.
To release the tubes loosen screws (see
D
, figure
2
) and then screw (see
E
, figure
3
).
Note
(QVXUHWKDWQHZMHWLV¿WWHGZLWKDQHZZDVKHUDQGWLJKWHQLQWRSODFH
Adjusting the primary air :
Ź
Put the burner in place and ignite it.
Ź
Lower the air ring to appropriate level for that gas type (see
F
, figure
4
), tabel
6
in appendix
0
.
(flame should be crisp, blue without any yellow).
/DFDQFKHUDQJHVDUHVXSSOLHGZLWKWKHDSSURSULDWHJDV¿WWLQJIRUWKHJDVW\SHVSHFL¿HGZKHQWKH
RUGHULRZHYHUWKHVHWWLQJPXVWEH¿QHWXQHG&200,6,21('ZKHQWKHFRRNHULV
installed.
The cooker is designed to operate with the gases in table
4
, appendix
0
.
IMPORTANT : Close the mains gas valve before carrying out any works.
IMPORTANT
In case of use with a gas other than that for which the cooker was initially set up, it is cru-
FLDOWRUHSODFHWKHLQMHFWRUVDQGPRGLI\WKHDGMXVWPHQWVDVGH¿QHGEHORZ
CHANGING GAS TYPE
wrench, 12
F
1
3
2
B
C
A
E
D
4