SECTION 1. CHECKLIST OF ITEMS 

Check that the following items have been supplied: 

 

1 extractor hood (Complete with blower motor, lighting, mains supply cord and grease filter(s) 

 

SECTION 2. EXTRACTION PERFORMANCE  

The most important influence on the performance of the extractor is the design of the ducting which takes the exhaust air from the 
extractor to the outside. The duct route should be a prime consideration during the initial stages of the kitchen design. Please note 
the following:  

 

The extractor is provided with a spigot(s) suitable for connecting 150mm diameter duct.  

 

Note:

 150mm is the minimum duct diameter consistent with efficient extraction. 

 

Double blower (fan) models will require two independent duct runs.

  

 

The exhaust duct route length should be kept as short as possible with as few bends as possible.  

 

The most efficient configuration is to duct straight through an outside wall so try to position the cooker against an outside wall 

when designing your kitchen layout.  

 

The hood is vented from the top exhaust. Use the position which gives the shortest duct route length and least number of 

bends. 

 

A route with more than two 90 bends will significantly degrade the performance of the extraction system. Keep bend radii as 

large as possible to maintain a smooth airflow without vortices; avoid kinks in flexible ducting; pull flexible ducting taut over 

straight runs to ensure that the internal surface is as smooth as possible. 

 

Rigid 150mm diameter (or equivalent rectangular) ducting should be considered for long or complex duct runs (which must be 

sourced separately). 

 

DO NOT REDUCE THE DUCTING DIAMETER OF 150MM AS THIS WILL REDUCE THE EXTRACTORS PERFORMANCE 

THIS COULD RESULT IN DAMAGE TO THE MOTOR WHICH WOULD NOT BE COVERED BY WARRANTY. 

 

 

SECTION 3. IMPORTANT INFORMATION

 

 

The following minimum headroom is required to accommodate the cooker and hood:  

Cooker height (nominal): 

900mm 

Cooker-to-hood clearance 

(min): 

750mm  

Hood height: 

325mm 

 

 

The minimum distance between the range hob burners and the bottom of the extractor is essential to prevent overheating of 

the extractor and its components. 

 

Please also note that a 90 deg bend in the flexible ducting will require 215mm minimum headroom to give a smooth radius 

with no kinking. 

 

If installing the BFUS900 extractor into a chimney it is recommended that the chimney must be lined and that the diameter of 

the chimney must be a minimum of 150mm. Consideration must be give to the length of the chimney, a long chimney will 

reduce the performance of the extractor.  

 

The exhaust air must not be discharged into a flue which is used for exhausting fumes from appliances supplied with energy 

other than electricity, e.g. oil or gas-fired central heating boilers, gas-fired water heaters, etc. 

 

Requirements of the relevant authorities concerning the discharge of exhaust air must be complied with.  

 

Adequate ventilation of the room must be provided when the cooker extractor and appliances supplied with energy other than 

electricity (e.g. gas-fired or oil-fired heaters, etc.) are used simultaneously. The room must be provided with vents to allow a 

constant flow of fresh air.  

 

Attention:

 

This appliance requires an earth connection

 

 

Ensure that the supply voltage corresponds to that marked on the rating label inside the extractor. 

 

The extractor must be isolated from the electrical supply before carrying out any cleaning or maintenance operations. 

 

If the power supply cable is damaged, it must be replaced by the manufacturer, its after-sales service, or a suitably qualified 

person. 

 

Pay particular attention to fire risk when frying. To minimise the risk of fire, all instructions relating to cleaning the grease 

filters and removing grease deposits must be adhered to. 

 

Do not flambé under the extractor. 

 

The hood has been designed to remove the kitchen smells; any other additional use shall be regarded as non-intended. 

 

This appliance is not intended for use by person (including children) with reduced physical, sensory, metal capabilities, or lack 

of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a 

person responsible for their safety. 

 

This appliance is for domestic use only.  

 

 

 

 

Содержание BFUS900

Страница 1: ...e instructions for BFUS900 High Performance Built in extraction systems FOURNEAUX DE FRANCE LTD 3 ALBION CLOSE NEWTOWN BUSINESS PARK POOLE DORSET BH12 3LL TEL 01202 733011 FAX 01202 733499 INFO FDEF CO UK WWW FDEF CO UK ...

Страница 2: ...NCE Page 1 SECTION 3 IMPORTANT INFORMATION Page 1 SECTION 4 INSTALLATION Page 2 SECTION 5 REMOVING AND REFITING THE GREASE FILTERS Page 4 SECTION 6 ELECTRICAL INSTALLATION Page 5 SECTION 7 WARNING Page 6 SECTION 8 OPERATING INSTRUCTIONS Page 7 SECTION 9 MAINTENANCE Page 8 ...

Страница 3: ...s and the bottom of the extractor is essential to prevent overheating of the extractor and its components Please also note that a 90 deg bend in the flexible ducting will require 215mm minimum headroom to give a smooth radius with no kinking If installing the BFUS900 extractor into a chimney it is recommended that the chimney must be lined and that the diameter of the chimney must be a minimum of ...

Страница 4: ...ear of the range the burners at the front of the range will not be covered by extractor and smoke spillage could occur The hood is mounted into the kitchen furniture or over mantle using a base board not supplied by FdeF Ltd and should be a minimum of 18mm thick the base board is fixed to the kitchen furniture or over mantle Ensure that the base board and kitchen furniture are of secure constructi...

Страница 5: ... louver to the outside wall Ensure that the air fins are directed downwards Fig 3 Connecting Ducting to ducting spigot Do not reduce the ducting diameter from 150mm as this will affect the performance of the hood and could damage the motor Damage caused to the hood by incorrect ducting will not be covered by warranty Fixing the Hood into the Over mantle and kitchen furniture Ensure that the base b...

Страница 6: ...Adjust lateral springs Fig 6 Warning Do not reduce the ducting diameter from 150mm as this will affect the performance of the hood and could damage the motor Damage caused to the hood by incorrect ducting will not be covered by warranty ...

Страница 7: ... extractor as per Fig 8 Pull the filter downwards away from the extractor To refit the grease filter position the rear of the filter into the grease tray as per Fig 9 then push the filter upwards until it locks into position Fig 8 Removing the Grease Filter Fig 9 Refitting the Grease Filter ...

Страница 8: ...ECTIONS Core Core Colour Live Brown Neutral Blue Protective Earth Green Yellow SECTION 7 WARNING Proper care must be taken to ensure that the negative pressures caused by high performance extraction systems do not adversely affect the safe operation of certain types of fuel burning appliances gas oil or solid fuel including those installed in the kitchen and possibly also those installed in other ...

Страница 9: ...ly When cleaning the grease filters it is vital that the grease tray is also cleaned The grease tray is designed to catch the grease from the open grease filters With the grease filters removed locate the grease tray fixing screws which can been found on the rear wall of the hood as per Fig 11 there are four fixings screws two per tray Release the fixings by hand or if necessary using a flat blade...

Страница 10: ...mps To replace the halogen lamp using a small flat blade screw driver gently easy the lamp away from the extractor as per Fig 14 Replace the bulb with the same rated type bulb 20w 12 volt halogen Fig 14 Replacing Halogen Lamp ...

Страница 11: ...l be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product please c...

Отзывы: