Labomed PRIMA ENT Скачать руководство пользователя страница 39

39

Prima ENT/DNT

This product is warranted by Labotech Microscopes India Pvt. Ltd. against defective material and workmanship 
under normal use for a period of one year from the date of invoice to the original purchaser. (An authorized 
dealer shall not be considered an original purchaser). Under this warranty, Labotech Microscopes India Pvt. 
Ltd. sole obligation is to repair or replace the defective part or product at Labotech/LABOMED discretion.

This warranty applies to new products and does not apply to a product that has been tampered with, altered in 
any way, misused, damaged by accident or negligence, or which has had the serial number removed, altered, or 
effaced. Nor shall this warranty be extended to a product installed or operated in a manner not in accordance 
with the applicable LABOMED instruction manual, nor to a product which has been sold, serviced, installed, 
or repaired other than by a Labotech Microscopes India Pvt. Ltd. factory or authorized LABOMED Dealer.

Charts, cards, and other expendable items are not covered by this warranty.

All claims under this warranty must be in writing and directed to the LABOMED factory or the authorized 
instrument dealer making the original sale and must be accompanied by a copy of the purchaser’s invoice.

This warranty is in lieu of all other warranties implied or expressed. All implied warranties of merchantability or 
fitness for a particular use are hereby disclaimed. No representative or other person is authorized to make any 
other obligations for a LABOMED product. Labotech/LABOMED shall not be liable for any special, incidental, 
or consequent damages for any negligence, breach of warranty, strict liability, or any other damages resulting 
from or relating to design, manufacture, sale, use, or handling of the product.

PRODUCT CHANGES

Labotech Microscopes India Pvt. Ltd. reserves the right to make changes in design or to make additions to or 
improvements in its products without obligation to add such to products previously manufactured.

CLAIMS FOR SHORTAGES

We use extreme care in selection, checking, rechecking, and packing to eliminate the possibility of error. If any 
shipping errors are discovered:
1.  Carefully go through the packing materials to be sure nothing was inadvertently overlooked when the unit 

was unpacked.

2.  Call the dealer you purchased the product from and report the shortage. The materials are packed at the 

factory and none should be missing if the box has never been opened.

3.  Claims must be filed within 30 days of purchase.

CLAIMS FOR DAMAGES IN TRANSIT

Our shipping responsibility ceases with the safe delivery in good condition to the transportation company. 
Claims for loss or damage in transit should be made promptly and directly to the transportation company.

If, upon delivery, the outside of the packing case shows evidence of rough handling or damage, the transportation 
company’s agent should be requested to make a “Received in Bad Order” notation on the delivery receipt. If 
within 48 hours of delivery, concealed damage is noted upon unpacking the shipment and no exterior evidence 
of rough handling is apparent, the transportation company should be requested to make out a “Bad Order” 
report. This procedure is necessary in order for the dealer to maintain the right of recovery from the carrier.

WARRANTY

24

Содержание PRIMA ENT

Страница 1: ...e of this instrument and to avoid injury during operation reading this manual before use is highly recommended PRIMA ENT DNT User Manual Operating Surgical Microscopy 6137000 795 PRIMA ENT DNT Issue 1...

Страница 2: ...LABOMED reserves the right to make changes to the product described in this user manual without notice and without incorporating those changes in any products already sold ISO 9001 13485 Certified LA...

Страница 3: ...nation Source 16 Replacing the Fuse 16 Data Plate Details 16 Prima Wiring Coding Diagram 17 9 Control Elements 18 10 Using the Microscope 19 20 11 Changing the Objectives and Eyepieces 21 12 Use of Ac...

Страница 4: ...gnification changer allows optimal magnification for various needs at five different magnification levels 3 Cold light illumination with a high intensity 50W LED lamp is provided using a fiber optic g...

Страница 5: ...ective CMO 5 Suspension arm 18 Magnichanger inclination 6 Swivel arm locking knob movement lock 7 Suspension arm movement locking knob 19 Illumination control knob 8 Coupling movement locking knob 20...

Страница 6: ...er inclination movement lock 6 Swivel arm locking knob 19 Illumination control knob 7 Suspension arm movement locking knob 20 Foot pedal for Z axis optional 8 Coupling movement locking knob 21 Fine fo...

Страница 7: ...MUST BE PERFORMED BY EXPERIENCED PERSONNEL OR DEALERS WHO ARE TRAINED BY LABOMED OR SERIOUS INJURY TO THE OPERATOR OR PATIENT MAY OCCUR WARNING MODIFICATIONS TO THIS INSTRUMENT ARE NOT ALLOWED ANY MO...

Страница 8: ...NG SOLUTIONS ON ANY PART OF THIS INSTRUMENT AS DAMAGE TO THE UNIT MAY OCCUR SEE THE CARE AND MAINTENANCE SECTION FOR DETAILED CLEANING INSTRUCTIONS CAUTION MEDICAL ELECTRONIC EQUIPMENT NEEDS SPECIAL P...

Страница 9: ...p dry the transport package shall be kept away from rain Year of manufacture used on product data plate Fragile contents of the transport package are fragile and should be handled with care Electromag...

Страница 10: ...d of view and direction of view of endoscopes with optics ISO 8600 5 First edition 2005 03 15 Optics and photonics Medical endoscopes and endotherapy devices Part 5 Determination of optical resolution...

Страница 11: ...ster wheels or other type of mounting 2 Column depending on the type of mount ordered 3 Swivel arm and suspension arm assembly with fiber optic cable 4 Inclined coupling with magnichanger assembly and...

Страница 12: ...move the tool kit and foam sheets as shown in Fig 2 3 Lift up the Center Support assembly as shown in Fig 3 4 Place the Center Support assembly on the floor as shown in Fig 4 5 Open one of the Wheel S...

Страница 13: ...upport with the holes of both Wheel Supports and tighten the screws as shown in Fig 8 using the 8 mm allen wrench 9 Remove 2 screws at center as shown in Fig 9 to remove the wooden block Unscrew with...

Страница 14: ...in Fig 2 3 Remove the arm assembly from the box and follow the instructions below see Fig 3 A Ensure that the swivel arm lock knob A is loosened B Place the arm assembly on the column shaft 1 shown in...

Страница 15: ...guide comes pre routed through the swivel arm which houses the LED illumination system and the suspension arm B Remove the dust cap from the receptacle C Insert the light guide into the receptacle in...

Страница 16: ...see A in Fig 8 with a new assembly C Resecure the arm covers 2 Replacing the Fuse A Locate the fuse at the AC inlet see Fig 9 B Use a flat head screw driver to open the fuse compartment Two fuses are...

Страница 17: ...17 Prima ENT DNT PRIMA WIRING CODING DIAGRAM...

Страница 18: ...ontrol knob 3 Swivel Arm Locking Knob This knob see B in Fig 10 locks the movement of the swivel arm at the desired position by turning it clockwise 4 Brakes Lock the stand to prevent unwanted movemen...

Страница 19: ...cking knob see B in Fig 10 above after focusing on the area of interest 4 Adjust the interpupillary distance IPD of the eyepieces as needed using the IPD adjustment knob 5 The illumination is controll...

Страница 20: ...lenses with focal lengths of 250 mm 300 mm 400 mm or variable working distance are avail able depending on the user s desired working distance A straight binocular head Prima ENT or ergo tilting binoc...

Страница 21: ...g it in a counterclockwise direction It can be attached by rotating it in a clockwise direction 2 To install the eyepieces insert them in the eye tubes of the binocular head 3 A range of objectives an...

Страница 22: ...cessories 4 Double Iris attachment An adjustable diaphragm attachment installed between magnichanger and observation head DBS DBSi It reduces incoming light and increased depth of field it is very use...

Страница 23: ...nt viewing 2 Attach the accessory to the left or right side of the beam splitter 3 DBS Abeamsplitter is inserted betweenmagnichanger and observation head Light is divided into two beams It can be 50 5...

Страница 24: ...n 4 After achieving the desired tension retighten the two screws shown in Fig 20 5 Reinstall the plate shown in Fig 19 THERMAL CUT OFF 13 The instrument is designed with safety provisions Fans in the...

Страница 25: ...g video monitor USB monitor and the camera control unit 4 Release the brakes 5 Be careful when passing through doorways to avoid collisions of any kind Do not move the instrument over steps or cables...

Страница 26: ...nts aldehydes alcohols and quaternary ammonium compounds Camera Keep the optical components clean using a microfiber cloth Soak the cloth using methanol or glass cleaner Do not use ethanol or 99 isopr...

Страница 27: ...use harsh or corrosive cleaning agents They can cause damage to the paint and plastic parts Avoid splashing water as it may cause damage to the device per the safety clause in IPXO Use 99 isopropyl al...

Страница 28: ...nsportation and storage Temperature Rel humidity without condensation Air pressure 40 C 70 C 10 100 500hPa 1 060hPa The unit meets the essential requirements stipulated in Annex I of the 93 42 EEC dir...

Страница 29: ...29 Prima ENT DNT DISPOSAL 18 Disposal of the instrument must comply with locally applicable laws and regulations...

Страница 30: ...ide properly to get maximum illumination Insufficient illumination Brightness level set too low Adjust the brightness control knob Light guide not properly inserted in arm of microscope Insert the lig...

Страница 31: ...system electronics Contact the service department Up and down motion of the suspension system is stiff The friction adjustment screw on the suspension system is tightened too firmly Loosen the frictio...

Страница 32: ...5x Objective f 250 mm manual fine focus Other working distance options available Light source 50W LED Built in filters Green and Yellow Vertical movement of arm 550 mm Microscope carriers 120 Carrier...

Страница 33: ...in such an environment Emissions Test Compliance Electromagnetic Environment Guidance RF Emissions CISPR 11 Group 1 The Prima ENT DNT uses RF energy only for its internal function Therefore its RF emi...

Страница 34: ...uality should be that of a typical commercial or hospital environment Surge IEC 61000 4 5 1kv Differential 2kv Common 1kv Differential 2kv Common Mains power quality should be that of a typical commer...

Страница 35: ...ance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance levels in each frequency range Interference may occur in...

Страница 36: ...ording to the maximum output power of the communications equipment Max Output Power of Transmitter W Separation m 150kHz to 80 MHZ d 3 5 v1 Sqrt P Separation m 80 to 800 MHZ d 3 5 E1 Sqrt P Separation...

Страница 37: ...37 Prima ENT DNT DIMENSIONS AND WEIGHT 22 Ceiling Mount Wall Mount Floor Mount 1 3 5 1 3 5 150 180 90 150 180 90 90 150 180 1 3 5 Prima ENT DNT Microscope with Mobile Stand Total Weight Approx 98 kgs...

Страница 38: ...cal tubes through which the enlarged image produced by the microscope can be viewed Convergent Beam Path The two light beams for the right and left eye run together at a point that lies at a distance...

Страница 39: ...not be liable for any special incidental or consequent damages for any negligence breach of warranty strict liability or any other damages resulting from or relating to design manufacture sale use or...

Страница 40: ...ica Inc 920 Auburn Court Fremont CA 94538 U S A T 510 445 1257 F 510 445 1317 sales laboamerica com LABOMED and Prima ENT DNT are registered trademarks of Labo America Inc With a policy of continuous...