User’s Manual eVA 500 / 500D COLPOSCOPE 

 
 

20

 

 

                                                                                                                                                                                                 

Issue

 

1.0

 

6169000

795

                                                          

eVO

 

500/500D

                                         

Printed

 

on

 

May,

 

2013

 

 

 

b) 

CHANGING THE MAGNIFICATION (Fig. 9) 

 

Adjust to the highest magnification with any of the rotating knobs 

① 

on the 

magnification changer 

.

 

 

 

See to it that the magnification changer step is engaged into its index position, related 
to the desired magnification.

 

 

 

 

 

1

2

 

(Fig. 9) 

 

 

Содержание eVA 500

Страница 1: ...Part No 6169000 795 Issue on 1 0 Printed on May 2013...

Страница 2: ...nnections 14 Changing of Fuse 14 7 Operating Instruction Control Elements Fig 5 15 16 8 Description of parts Fig 7 1 7 2 17 18 9 Instructions for using the Microscope a Adjustment of Interpupillary di...

Страница 3: ...t Contact information is provided at the end of this guide LABOMED eVA 500 500D COLPOSCOPE is an optical instrument used in a medical diagnostic procedure to examine Cervix Vaginal and Vulva tissue wi...

Страница 4: ...g the required height Ez lift knob is used for fine perfect position of colposcope to view the desired field with comfort ease of both user and patient It has a total fine adjustment travel of 25 mm E...

Страница 5: ...nt User can adjust colposcope as per convenience for exact view of interest S50 stand also has a foldable provision when not in use to park in a compact position Magnichanger CMO Green Filter Knob Foc...

Страница 6: ...thisUser s Gu TTENTION T L LAW AND EU A PHYSICIAN HOULD BE U USER S GUID T CANNOT BE ERVICE THIS EPAIR OR S NNEL OR DEA OR PATIENT M S INSTRUMEN BY LABOMED MODIFIED UED SAFE USE ELECTRIC SH H PROTECTI...

Страница 7: ...T IS OF LABOMED 500 500 eVO 500 500D RADIATION 4 H BLUE LIGHT IES OR CABL MANUFACTUR CREASED EM ENTIONTOTH ITRY OF TH ESDS THAT DO NOT REM OR STRONG NIT MAY OCCU QUIPMENT NE AND PUT IN OMPANYING RF CO...

Страница 8: ...ed repres plate bel plate indi he unit er age and curr uency range ber mpliance me ol on has been iber illumina cuments mus dical device on illuminati knob ates correct rt package s acronym for Europe...

Страница 9: ...t For USA FDA classification Class II IEC 60601 1 2005 3rd edition Compliance Please observe all applicable accidental prevention regulations Intended use LABOMED colposcope eVA 500 and eVA 500D is a...

Страница 10: ...MATERIAL AT TIME OF SUPPLY The appliance is delivered in 6 assembled groups Mobile supporting Base Column S50 0r E50 Illumination box with integrated electrical power supply Swivel Arm S50 0r E50 Micr...

Страница 11: ...ND AND COLUMN Fig 1 Insert column into the mobile base Fasten screw with enclosed hexagon socket wrench to column The mobile bases have 5 rollers out of two have locking breaks red Indication The colp...

Страница 12: ...inted on May 2013 4 2 MOUNTING OF APPLIANCE Mount the illumination box to the column against the vertical guide Screws to be tighten to hold the box as shown Fig 2 1 1 2 3 Fig 2 1 Insert swivel arm on...

Страница 13: ...Instruction The joint which connectsswivel arm and the column is fitted with a stop to prevent the inner assembled cables The total rotation of the swivel arm is not more than 180 to the column On re...

Страница 14: ...500D Printed on May 2013 5 DIMENSIONS WEIGHT Fig 3 eVA 500D Digital Colposcope with roller stand Total weight Approx 45 kg eVA 500 Colposcope with roller stand Total weight Approx 44 kg 1127 525 980...

Страница 15: ...on on electrical label provided at back of illumination box as shown in figure number 4 below a CHANGING OF FUSE Note Fuses are in fuse holder F 2 5 A 2 mains input fuses for lamp supply for mains vol...

Страница 16: ...r a ableshown a arm to dire own as f life switch o 500 500 VO 500 500D g 6 is locat d on the gr eration The and light inte as in fig ect the light facilitates to off the micro Fig 5 D COLPOSC ted on t...

Страница 17: ...User s Manual eVA 500 500D COLPOSCOPE 16 Issue 1 0 6169000 795 eVO 500 500D Printed on May 2013 7 5 BRIGHTNESS CONTROL Fig 6 A variation in light intensity is made by rotating knob 1 Fig 6...

Страница 18: ...ize If required Common Main Objective CMO IPD knob to change interpupillary distance by turning it laterally SD card slot Only in eVA 500D Button to capture the image Only in eVA 500D Fine focusing kn...

Страница 19: ...3 Ez lift control knob with E50 column configuration Swivel arm locking knob Column height adjustment knob E50 stand and Column height adjustment handle S50 stand Inlet for fiber optic cable Knob to s...

Страница 20: ...RUCTIONS FOR USING THE MICROSCOPE a ADJUSTMENT OF INTERPUPILLARY DISTANCE Fig 8 Turn the microscope in working position Inclined tube 45 Adjust eyepieces to the required IPD by turning the lateral kno...

Страница 21: ...rinted on May 2013 b CHANGING THE MAGNIFICATION Fig 9 Adjust to the highest magnification with any of the rotating knobs on the magnification changer See to it that the magnification changer step is e...

Страница 22: ...he fine focusing knob bring the complete microscope in the focus range by any of the following means a Roll the mobile stand forward and backward b Adjust the swivel arm towards left and right c Adjus...

Страница 23: ...inted on May 2013 d Red free image observation Fig 9 2 Rotate filter knob 1 to swing in or swing out the red free Green filter This will help in filtering the red tissue in the image being observed an...

Страница 24: ...9 3 LABOMED eyepieces have a unique locking facility Diopter lock can be released by moving the slider on eyepiece toward right You can adjust the diopter settings as per your vision correction Once...

Страница 25: ...0 6169000 795 eVO 500 500D Printed on May 2013 f APERTURE SETTINGS FOR THE COLPOSCOPE Fig 9 4 To increase the contrast and depth of focus while working at higher magnification the aperture knob can be...

Страница 26: ...NGING THE BINOCULAR TUBE Fig 10 Loosenthe knob from the top of the head arm to remove the inclined tube 45 or the straight tube When setting up the binocular tube two plugs should lock into the nuts o...

Страница 27: ...on May 2013 11 CHANGING THE OBJECTIVE EYEPIECES Fig 10 1 The objective 1 has screw type mounting Unlock it by turning anti clock wise and lock them by turning clock wise Eyepieces 2 are inserted draw...

Страница 28: ...hemicals close to the instrument o Protect it from improper handling Never install other devices sockets or unscrew optical system and mechanical parts unless explicitly instructed to do so in this ma...

Страница 29: ...rface with running water 40 C using a little detergent if necessary o Also use spirits to clean optical components o Dry optical components using a microfiber cloth dry the rest of the product using a...

Страница 30: ...User s Manual eVA 500 500D COLPOSCOPE 29 Issue 1 0 6169000 795 eVO 500 500D Printed on May 2013 Schedule of Autoclavable caps 1 2 3 4 5 6 7 8 C1 C2 C2 C3 C4 C5 C7 C6 C8 Fig 11...

Страница 31: ...700hPa 1 060hPa For transportation and storage Temperature Rel humidity without condensation Air Pressure 40 C 70 C 10 100 500hPa 1 060hPa The Unit meets the essential requirements stipulated in Anne...

Страница 32: ...opter lock anti fungal Wide field 10x 18mm FOV focusable with retractable eye guards diopter lock anti fungal Apochromatic Magnichanger 5 Step 0 4x 0 6x 1 0x 1 6x 2 5x 5 Step 0 4x 0 6x 1 0x 1 6x 2 5x...

Страница 33: ...nt Labotech Microscopes India Pvt Ltd reserves the right to change design and specification without prior notice Labo America Inc 920 Auburn Court Fremont CA 94538 U S A Telephone 510 445 1257 Fax 510...