Labnet Spectrafuge 6C Скачать руководство пользователя страница 3

Table of Contents

1.  General Information

1

Description
Safety precautions
Technical data
Accessories supplied with unit
Warranty

2.  Installation

2

Unpacking the centrifuge
Required space
Installing the centrifuge

3.  Installing the Rotor

3

Rotors and accessories
Rotor maintenance
Removing and installing the angle rotor
Overloading rotors

4.  Operation

6

Closing the lid
Lid release
Lid lock
Speed selection
Selection of operating time and momentary operation
Starting the Centrifuge

5.  Service and Maintenance

8

Service
Cleaning
Disinfection
Replacing fuses

6.  Troubleshooting

9

7.  Where to Call

10

8.  Determination of g-values

10

To use this chart, find the radius value on the radius scale.  Place the
edge of a ruler on the value. Place the right side edge of the ruler on the
speed scale at the desired speed.  The estimated RCF can then be read
from the RCF scale where the ruler edge passes through it.  This chart
can also be used to determine the proper speed for the desired RCF
value.

11

Содержание Spectrafuge 6C

Страница 1: ...rafuge 6C Spectrafuge 6C Spectrafuge 6C Spectrafuge 6C Spectrafuge 6C Compact Centrifuge Labnet International PO Box 841 Woodbridge NJ 07095 Phone 732 417 0700 Fax 732 417 1750 Email labnet labnetlink...

Страница 2: ...rotor area unless the rotor is completely stopped NEVER move the centrifuge while the rotor is spinning NEVER use solvents or flammables near this or other electrical equipment NEVER centrifuge flamma...

Страница 3: ...ed selection Selection of operating time and momentary operation Starting the Centrifuge 5 Service and Maintenance 8 Service Cleaning Disinfection Replacing fuses 6 Troubleshooting 9 7 Where to Call 1...

Страница 4: ...properly balanced 1 Possible reason Lid lock is jammed Solution Call for service Possible reason Centrifuge is not receiving power Solution See Centrifuge will not start Centrifuge cannot be started a...

Страница 5: ...aning the rotor The rotor should be cleaned after each use When spinning samples containing phenol or phenol chloroform the rotor should be cleaned immediately after use 5 4 Disinfection Should a spil...

Страница 6: ...of operating time and momentary operation Time can be selected in half minute intervals from 0 5 to 10 minutes and in one minute intervals from 11 to 30 mintes Time can also be set to continouos hold...

Страница 7: ...on the large LED display right Figure 4 Spectrafuge controlpanel layout 7 Tube and tube adapter reference chart 3 2 Rotor maintenance The rotor should be cleaned thoroughly after each use Thor ough cl...

Страница 8: ...sult in damage to the rotor and centrifuge The revised maximum speed can be calculated with the following formula Reduced speed nred x max speed nmax Example Where the density of the liquid is 1 7 the...

Отзывы: