background image

1.4

Accessories
Accessories supplied with each centrifuge unit:
-  One 6 x 15ml rotor     - One Instruction manual
-  One Warranty card     - Six Rubber Cushions

                   Aditional accessories available:

C0200-17A - Combination adapters for 5ml and 7ml tubes, (6pk.)
C0230-17A - Combination adapters for 5ml and 7ml tubes, (4pk.)

1.5

Warranty
This centrifuge has been subject to thorough testing and quality control.
In the unlikely event of any manufacturing faults occuring, our  one
year warranty (from date of delivery) covers the centrifuge and the
rotors. This warranty becomes void in case of incorrect operation, use
of non-appropriate spare parts or accessories and non-authorized
modification of the rotor or the centrifuge.

2.  Installation

2.1

Unpacking the centrifuge
The centrifuge is delivered in a carton with two or more formed foam
blocks.   Please retain the carton and the blocks until it has been
established that  your unit is working  properly.

The accessories supplied with the centrifuge should be kept with the
instruction manual near the centrifuge's place of installation.

2.2

Required space
The centrifuge should be installed on a rigid, even surface.  The Z100-A
should only be operated on a stable laboratory table/bench  etc.
To guarantee sufficient ventilation, please ensure that the centrifuge has
at least 15 cm free space on all sides, including the rear.

It is recommended that the centrifuge is not situated in a location
subject to excessive heat, e.g. strong sunlight, radiators etc. as heat-build-
up can occur within the centrifuge bowl.

2.3

Cushion Installation
Before inserting any tubes into the centrifuge the rubber cushions must
first be properly installed.  To install the cushions turn a 10 or 15ml round
bottom tube upside down and place the cushion on top.  Then remove the
rotor sheild and place it on top of the tube while pushing the cushion into
the end of the sheild.  Then reinsert the shield.

3

Содержание C0100-A

Страница 1: ...INSTRUCTION MANUAL FOR THE Z100 A CLINICAL CENTRIFUGE C0100 A January 2005...

Страница 2: ...3 2 4 CentrifugeInstallation 4 3 Operation 4 3 1 Closing the lid 4 3 2 Lidrelease 4 3 3 Lid lock 4 3 4 Startingthecentrifuge 4 4 Proper use of the Rotor 4 1 Overloading the rotor 5 4 2 Balancing the r...

Страница 3: ...without the prior permission of the manufacturer Exception tubes and bottles made of glass or plastic normally available in the laboratory and designed for centrifugation The centrifuge is to be used...

Страница 4: ...blocks until it has been established that your unit is working properly The accessories supplied with the centrifuge should be kept with the instruction manual near the centrifuge s place of installa...

Страница 5: ...ected in order to start the centrifuge The speed rpm can be selected between 1 000 and 4 000 rpm by turning the knob to the 1 2 3 and 4 speed marks To select a speed turn the speed knob to the 2 posis...

Страница 6: ...may operate a 6 place rotor with 2 3 or 4 loaded tubes but it is important that the occupied tube shields are symetrically arranged see sketch A 4 2 When loading the rotor you should proceed accordin...

Страница 7: ...cohol or other disinfecting agents Do not allow the alcohol or disinfectant to sit on the units lid or housing as it may affect or discolor the plastic 5 4 Cleaning the centrifuge after breakage of gl...

Страница 8: ...Check and set the time or speed Possible reason Blown fuse Solution Check fuse and replace if necessary see 5 5 Should you have any questions about the centrifuge and its accessories or require servic...

Страница 9: ...alues See section 1 3 for the correct radius of your rotor Note the use of tube adapters will change thisradius To determine the relative centrifugal force RCF value Thisvalueisthemultipliertothegravi...

Отзывы: