Labnet BioPette PLUS Скачать руководство пользователя страница 25

Instruction Manual – 23

 13.  Limited  Warranty

Corning Incorporated (Corning) warrants that this product 

will be free from defects in material and workmanship for 

a period of three (3) years from date of purchase. CORNING 

DISCLAIMS ALL OTHER WARRANTIES WHETHER EXPRESSED 

OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF 

MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR 

PURPOSE. Corning’s sole obligation shall be to repair or 

replace, at its option, any product or part thereof that 

proves defective in material or workmanship within the 

warranty period, provided the purchaser notifies Corning 

of any such defect. Corning is not liable for any incidental 

or consequential damages, commercial loss or any other 

damages from the use of this product.
This warranty is valid only if the product is used for its 

intended purpose and within the guidelines specified 

in the supplied instructions manual. This warranty does 

not cover damage caused by accident, neglect, misuse, 

improper service, natural forces or other causes not arising 

from defects in the original material workmanship. 

This warranty does not cover the O-ring, or shaft. 

Claims for transit damage should be filed with the 

transportation carrier.
In the event this product fails within the specified period of 

time because of a defect in material or workmanship, contact 

Corning Customer Service at: 

[email protected]

visit 

www.labnetlink.com

, or contact your local support office.

Corning Customer Service will help arrange local service 

where available or coordinate a return authorization 

number and shipping instructions. Products received 

without proper authorization will be returned. All items 

returned for service should be sent using prepaid postage 

in the original packaging or other suitable carton, padded 

to avoid damage. Corning will not be responsible for 

damage incurred by improper packaging. Corning may 

elect for onsite service for larger equipment.
Some states do not allow limitation on the length of 

implied warranties or exclusion or limitation of incidental 

or consequential damages. This warranty gives you specific 

legal rights. You may have other rights which vary from state 

to state.
No individual may accept for, or on behalf of Corning, any 

other obligation of liability, or extend the period of this 

warranty.

Содержание BioPette PLUS

Страница 1: ...Labnet BioPette Plus Single channel 8 channel and 12 channel Pipettors Instruction Manual This manual is available in additional languages at www labnetlink com...

Страница 2: ...mendations 4 5 Specifications 5 6 Pipettor Operation 7 7 Operating Instructions 11 8 Aspiration and Dispensing Instructions 12 9 Checking Pipetting Accuracy Parameters and Pipettor Recalibration 14 10...

Страница 3: ...0 200 L and 50 300 L Nominal Volume L Cat No Range of Pipettor Volumes L Single channel pipettors 2 P3942 2 0 1 2 10 P3942 10 0 5 10 20 P3942 20 2 20 100 P3942 100 10 100 200 P3942 200 20 200 1 000 P3...

Страница 4: ...pettor models P3942 5000 P3942 10000 3 Filters The 5 000 L and 10 000 L pipettors include a replaceable filter fitted at the bottom of the shaft which prevents aspirated liquid from entering the shaft...

Страница 5: ...me setting to be locked by pushing the ring upwards C Shaft Manufactured using high quality plastic ensuring high chemical and mechanical strength D Tip ejector For multi channel pipettors the tips ar...

Страница 6: ...in the tip Only using the pipettor in accordance with the manufacturer s instructions ensures the correct pipettor parameters are maintained After replacing the plunger or the shaft the pipettor shoul...

Страница 7: ...bility accuracy and precision when pipetting Nominal Volume L Volume L Accuracy Precision Non filter Tips L Single channel Pipettors 2 Min 0 1 40 0 12 0 10 0 2 12 0 6 0 1 2 7 1 3 Max 2 1 5 0 7 10 Min...

Страница 8: ...6 8 300 12 300 Min 50 1 6 1 5 300 150 1 2 1 0 Max 300 1 0 0 6 The accuracy and precision were obtained gravimetrically using manufacturer tips performing at least 10 measurements of distilled water a...

Страница 9: ...s approximately 1 5mm into the manifold The suspension system ensured even and airtight sealing of the pipet tips The rocking motion does not have to be performed to seal the pipet tips tightly NOTE D...

Страница 10: ...e ejector from the plastic arbor 2 Tip ejector assembly Press the tip ejector pushbutton Line the tip ejector up with the plastic arbor Turn the tip ejector bush clockwise until it has fully latched 3...

Страница 11: ...ctor 2 Tip ejector assembly Remove the tip ejector pushbutton Using a screwdriver turn the metal arbor clockwise to secure the ejector and adjust its length NOTE Leave a space of at least 1mm between...

Страница 12: ...he cap upwards to the bottom of the tip ejector M M Volume Setting 1 2 3 1 To enable volume selection set the locking ring to the lower position 2 Aspiration volume can be set by either turning the pi...

Страница 13: ...ing Instructions Observing the following recommendations will ensure maximum possible accuracy and precision of liquid sampling During operation the volume setting should be locked with black adjustme...

Страница 14: ...inse the tip several times prior to use Do not pipettor liquids with temperatures above 70 C NOTE When pipetting acids or corrosive solutions which emit vapors it is recommended to disassemble the sha...

Страница 15: ...id may be formed on the inside of the pipet tip which may produce erroneous results As the film remains relatively constant in successive pipetting operations with the same tip this error can be elimi...

Страница 16: ...tors are designed to enable recalibration and adaptation to different pipetting techniques and liquid properties e g temperature density and viscosity Periodic checks of the operation of the pipettor...

Страница 17: ...alance sensitivity should be suitable for the volume V to be measured Volume Checked V L Balance Sensitivity mg 0 1 V 10 0 001 10 V 100 0 01 100 V 1 000 0 1 V 1 000 0 1 When calculating the liquid vol...

Страница 18: ...1 94 2 06 0 63 0 0262 100 10 9 84 10 16 2 50 0 104 200 20 19 76 20 24 6 30 0 262 1 000 100 98 4 101 6 25 00 1 04 5 000 500 494 506 125 00 5 2 10 000 1 000 975 1 025 250 00 10 4 8 channel and 12 channe...

Страница 19: ...he aspirated volume Use the values given in the above table to precisely adjust the volume 4 Remove the key and replace the pipetting pushbutton by first replacing the knob then the pushbutton Determi...

Страница 20: ...than those recommended by the manufacturer check the compatibility charts and consider chemical resistance of the following plastics which form components of the pipettor PP PC POM PA PPS PVDF Sterili...

Страница 21: ...ing the instructions provided Replacement of parts should be required only occasionally and should not be required with normal pipettor use Problem Cause Solution Droplets of liquid remain in the pipe...

Страница 22: ...ts blocked The inside of the pipettor is contaminated due to aspiration of corrosive substances Unscrew the shaft set wash the parts Replace the elements with new ones if necessary Apply a small amoun...

Страница 23: ...low NOTE The replacement of the plunger requires conducting the calibration procedure according to Section 9 G L I J S C D F P G B M Item Description Model Cat No Qty Pk B Volume adjustment knob set A...

Страница 24: ...P19384 1 200 SP19385 1 1 000 SP19386 1 5 000 SP19388 1 10 000 SP19389 1 I J O ring and seal 2 SP19101 10 10 SP19102 10 20 SP19103 10 100 SP19104 10 200 SP19105 10 1 000 SP19106 10 5 000 SP19108 5 10 0...

Страница 25: ...inal material workmanship This warranty does not cover the O ring or shaft Claims for transit damage should be filed with the transportation carrier In the event this product fails within the specifie...

Страница 26: ..._________________ Date Purchased ___________________________________________ Supplier _________________________________________________ Warranty Disclaimer Unless otherwise specified all products are...

Страница 27: ...PAC I FIC Australia New Zealand t 61 427286832 Chinese Mainland t 86 21 3338 4338 f 86 21 3338 4300 India t 91 124 4604000 f 91 124 4604099 Japan t 81 3 3586 1996 f 81 3 3586 1291 Korea t 82 2 796 95...

Отзывы: