Label Sensor
Blank label under sensor
Note:
The difference in value of “Ref. Level” when sensing the mark should be greater than when sensing blank label
by no less than 128. If the sensor fails to differentiate by this much, manually increase Intensity until the above
difference is achieved.
BLine Mode
Complete
Intensity
X
Ref. Level
XXX
5. BLine sensor calibration is complete. Press the
SELECT
key to return the LCD screen to the previous menu.
B-3 Pre-Printed
This function auto-calibrates the black line sensor more accurately for pre-printed labels.
Entering the Pre Printed option displays the following message, with steps which must be completed:
Mode
Actions
Paper Len.
00812 dot
1. Press the
DOWN
key
to move the cursor from left digit to
right digit, and press the
UP
key
to set the value from “0” to “9”
and the “dot/ mm/ inch”. Press the
SELECT
key to set the paper
length.
BLine Size
0024 dot
2. Press the
DOWN
key
to move the cursor from left digit to
right digit, and press the
UP
key
to set the value from “0” to “9”
and the “dot/ mm/ inch”. Press the
SELECT
key to set the gap
size.
BLIne Mode
Pre Printed
3. The printer feeds labels to calibrate the sensor sensitivity
automatically. When calibration is complete, the LCD screen will
return to the previous menu.
BLine Mode
3/4
Manual
>
Pre Printed
Exit