LM3606 PRINT & APPLY SYSTEM
USERS MANUAL
Page 22
Made in the U.S.A.
© 2021 LabelMill
06/01/2021 Model LM3606
TAMP FLOW CONTROL ADJUSTMENT
Regulator Adjustment:
Clockwise
- Increase pressure
Counterclockwise
- Decrease pressure
FLOW CONTROLS
(tamp and flag applications)
Control A: This is used to adjust the pressure that controls the tamp cylinder in the upward direction.
Control B: Controls the tamp cylinder in the downward direction.
Valve Pack Regulators
MAIN AIR REGULATOR
Controls maximum air pressure available to entire applicator. Should be set between 40 and 80 PSI.
FLAG REGULATOR
The flag regulator is used to adjust the pressure that the flag jaws apply to the label as it is applied.
VACUUM REGULATOR
(only used on the flag and tamp applicator system)
The vacuum regulator is used to control the vacuum that is used to hold the label to the flag jaws or
the tamp pad.
AIR ASSIST REGULATOR
The air assist regulator is used to change the pressure that is applied to the blow tube. The blow tube
is below the front edge of the peeler plate and is used to help “push” the label onto the bottom of the
tamp pad or the flag jaws.
2-13