MEMORY EVENTS
Message of warnings or errors that can be read by digital programmer N-DSEL
( E1-E2-E3-E4-E5)
WARNINGS
SIMBOL
SCREEN MESSAGE
MEANING
SOLUTION
RESET SOFTWARE
OBSTACLE IN OPENING
OBSTACLE IN CLOSING
RESET 4 OBSTACLE
IN CLOSING
Generic malfunction that caused a reset of
the microcontroller.
The door detect an obstacle during the
opening cycle that caused the reversal
direction of the leaf.
The door detect an obstacle during the
closing cycle that caused the reversal
direction of the leaf.
If, during closing, the door detect an obstacle
at the same point for 4 consecutive times, a
reset occurs with subsequent opening at slow
speed.
There is an automatic recovery system in case of
temporary malfunction.
If the problem persists, check if there is any obstacle
that stop the door and remove it, or control the
smoothness of the leaf.
If the problem persists, check if there is any obstacle
that stop the door and remove it, or control the
smoothness of the leaf.
Remove the obstacle that prevents the complete
closure of the door.
ERRORS
SIMBOL SCREEN MESSAGE MEANING SOLUTION
FAULT CURRENT
FAULT POWER
The system automatically resets and, after a few seconds,
The cyclical testing of the detection circuit
repeat again the test. If the problem persists it is a defect
current has failed.
on the logic board L-NEP.
The control of the driving signal of the motor
The system automatically resets nd, after a few seconds,
has detected a fault
.
repeat again the test. If the problem persists it is a defect
on the logic board L-NEP.
ERROR INITIAL SET UP
ERROR ENCODER
OR MOTOR
FAULT ENCODER
ERROR SAFETY SENSOR
IN OPENING
ERROR SAFETY SENSOR
IN CLOSING
The operator is not able to finish the initial
set-up.
Encoder signals are not detected or the
motor does not turn.
Fault detected during the test operation of
the encoder.
The test on the safety opening sensor is failed.
The test on the safety closing sensor is failed.
Control the smoothness of the door and that there are
no obstacles along the way, that motor and encoder
are connected and try again to set-up the door.
Check that the cables and connector of the motor and
encoder are well inserted and not damaged.
The system automatically resets, and repeat again the
test at the first cycle. If the problem persists it is a defect
on the logic board L-NEP.
Verify that the settings and parameters related to the
safety sensor test are correct, on the operator and on
the sensor.Also check that the electrical connection
between the sensor and controller are correct.
Verify that the settings and parameters related to the
safety sensor test are correct, on the operator and on
the sensor.Also check that the electrical connection
between the sensor and controller are correct.
FAULT BRAKING
FAULT EEPROM REGISTER
ERROR COMMUNICATION
MASTER-SLAVE
GENERAL ERROR SLAVE
The system automatically resets and repeat again the test
The control of the braking during closing cycle
in every cycle. If the problem persists it is a defect on the
has detected a fault.
logic board L-NEP.
The test of the internal memory cells related to The system automatically resets and, after a few seconds,
repeat again the test. If the problem persists it is a defect
the safety parameter has failed.
on the logic board L-NEP.
The communication line between master
Check that the WR5MS cable is connected between
and slave is missing.
master and slave and that the configuration setting for
(with double door only)
double swing unit is correct.
A fault is present on the slave operator.
Access memory events on the slave operator and check
(with double door only)
what type of problem is displayed.
Содержание Vista SMP
Страница 56: ...VISTA SMP Made in UK ...