4) PROGRAM SELECTORS
The program selector allows the user of the door to select the operating mode.
Depending on the preference, it is possible to use the manual selector incorporated in the side panel of the automation NEXT 75, the
mechanical key selector EV-MSEL, or the digital programmer ET-DSEL or T-NFC.
Each program selector is fully described below.
4.1) MANUAL PROGRAM SELECTOR
The 3-position manual PROGRAM selector is the basic solution provided on the automation.
Position
I
=
Automatic bidirectional program
The door automatically opens when each opening control activates.
Position
0
=
Manual free door
Automatic operation is disabled and the door can be opened manually.
Position
II
=
a) Night lock program
The door can only be opened through the OPEN input or using the remote
control.
b) Open door program
The door remains stationary in complete opening position.
4.2) EV-MSEL MECHANICAL KEY SELECTOR
OPERATING MODE
Insert and turn the key of selector EV-MSEL to select the desired program.
Open door program
The door remains stationary in complete opening position.
Manual free door
Automatic operation is disabled and the door can be opened manually.
Automatic bidirectional program
The door automatically opens when each opening control activates.
Automatic unidirectional exit only program
To exclude the incoming detection on external radar input.
Night lock program
The door can only be opened through the OPEN input or using the SPYCO remote control, if any.
The key can be taken out of the selector when in any position in order to prevent undesired changes to the work program.
It can operate in two