background image

10

4.6) ET-DSEL SELECTOR USER PASSWORD MANAGEMENT 

To prevent the door work program from being modified, you can enter a password every time the ET-DSEL programmer is used.

To enable the password perform the operations listed below:

  1.  Press and hold the SET button for 5 seconds to access the general programming menu (see Diagram 1 at para. 4.3.1)

  2.  Press the F1 button five times to switch to the Password Management sub-menu.

  3.  Press the Enter   button to access the “Password management” section.

PASSWORD MANAGEMENT

PRIMARY PASSWORD (for the system owner-user)

It is a 5-character password used by the user to prevent unauthorized persons from having access to the ET-DSEL programmer and 

change the work program.

Using a primary password is optional and must be enabled by system owner.

The default technical password is “A-A-A-A-A”.

WARNING!

When enabling the password, be very careful not to forget the access combination.

SERVICE PASSWORD (for user)

It is a 5-character password that the system owner can provide to persons authorized to use the ET-DSEL programmer.

With the service password, it is only possible to change the work program of the automatic door.

The default service password is “A-A-A-A-A”.

To change the service password, it is necessary to log in using the primary password.

Use the

 

 

button to move the selection arrow downward, the F2 button to move back upward.

HOW TO CHANGE THE PRIMARY PASSWORD

• 

Select “PRIMARY PASSWORD”

• 

Press OK (F1).

• 

Enter the default primary password “A-A-A-A-A” by pressing 5 times the A button.

(If the primary password is not the default password, since it had already been changed before, 

enter the currently used primary password).

• 

Enter the new primary password, selecting a combination of 5 characters from A-B-C-D.

This section displays the two passwords available to the final user, the primary password and the 

service password.

The technical password is reserved for the technical staff in charge of installation and maintenance 

operations.

• 

You are prompted to repeat the new password, so enter again the previous combination.

• 

If the password entered is correct, the “PASSWORD OK” message appears on the display for 

one second, then the system returns to the PASSWORD MANAGEMENT section; press the EXIT 

 button to return to the general programming menu

• 

If the password you entered does not match the previous one, the display shows PASSWORD 

ERROR, the system returns to the section PASSWORD MANAGEMENT and it is necessary to 

perform again the procedure.

Содержание NEXT 75

Страница 1: ...USER MANUAL NEXT 75_Eng_Rel 1 0_01 2019 CD0750En MU TRANSLATION OF THE ORIGINAL INSTRUCTIONS NEXT 75 Automation for interior swing doors En ...

Страница 2: ...o responsibility for incorrect product usage as well as for any damages arising from changes to the system made without its prior consent When operating the system accident prevention regulations must be observed REMARKS Always meet the usage and maintenance conditions provided for by LABEL Maintenance and repair operations must only be performed by qualified and properly trained personnel PROPER ...

Страница 3: ...1 MANUAL PROGRAM SELECTOR 6 4 2 EV MSEL MECHANICAL KEY SELECTOR 6 4 3 ET DSEL DIGITAL PROGRAM SELECTOR 7 4 4 T NFC DIGITAL PROGRAM SELECTOR 8 4 5 ET DSEL SELECTOR GENERAL PROGRAMMING MENU 9 4 6 ET DSEL SELECTOR USER PASSWORD MANAGEMENT 10 4 7 T NFC SELECTOR USER PASSWORD MANAGEMENT 12 4 8 LANGUAGE 13 5 OPERATION IN CASE OF POWER SUPPLY FAILURE 13 6 NOTIFICATION OF ERRORS AND OPERATION PROBLEMS 14 ...

Страница 4: ...NG NEXT 75 AUTOMATION ELECTRIC LOCK FLOOR STOP 2 TECHNICAL DATA AUTOMATION MODEL NEXT 75 POWER SUPPLY 115 230 50 60Hz POWER 40W AUTOMATION DIMENSIONS L x H x D 420 x 60 x 74 mm FREQUENCY OF USE continua OPERATING TEMPERATURE 15 C 50 C ELECTRIC MOTOR Brushless 24Vdc POWER SUPPLY OF EXTERNAL ACCESSORIES 24Vdc 1A STAND BY CONSUMPTION 5W CLASS APPLIANCE class II MISSION SOUND PRESSURE LEVEL LpA 70dB A...

Страница 5: ... manual thrust If the closing safety sensor detects a presence the door immediately reopens and stays open as long as the sensor remains engaged If the opening safety sensor detects a presence the door stops and remains still for the entire period during which the sensor remains engaged it will complete the opening cycle only after the sensor is disengaged If during the opening motion the door col...

Страница 6: ...gh the OPEN input or using the remote control b Open door program The door remains stationary in complete opening position 4 2 EV MSEL MECHANICAL KEY SELECTOR OPERATING MODE Insert and turn the key of selector EV MSEL to select the desired program Open door program The door remains stationary in complete opening position Manual free door Automatic operation is disabled and the door can be opened m...

Страница 7: ...artial opening press the button once The symbol on the display indicates that the function is on In a double leaf door only the first leaf Master opens if the opening command is given by the internal or external radar inputs The partial opening only operates in bi directional single direction and open door automatic programs In order to disable partial opening press again button F2 Can have two di...

Страница 8: ...am press the SET button once to exit from the Screen Saver function and thus make the selector active the screen will increase its brightness now press SET again several times until you position on the desired work program If you have activated the program lock with the SLIDE function to exit from the Screen Saver slide your finger from left to right on the buttons A SET B to activate the selector...

Страница 9: ...rd to prevent any unauthorised access to the ET DSEL digital programmer DIAGRAM 1 SECTION RESERVED FOR TECHNICAL STAFF SECTION RESERVED FOR TECHNICAL STAFF SECTION RESERVED FOR TECHNICAL STAFF PASSWORD MANAGEMENT SECTION SECTION RESERVED FOR TECHNICAL STAFF SELECTOR OPTIONS SECTION NOT USED LANGUAGE SECTION The paragraphs below explain the procedure to be followed to manage the user password and t...

Страница 10: ...he automatic door The default service password is A A A A A To change the service password it is necessary to log in using the primary password Use the button to move the selection arrow downward the F2 button to move back upward HOW TO CHANGE THE PRIMARY PASSWORD Select PRIMARY PASSWORD Press OK F1 Enter the default primary password A A A A A by pressing 5 times the A button If the primary passwo...

Страница 11: ... return to general programming menu If the password entered does not match the previous one the display shows PASSWORD ERROR the system returns to the section PASSWORD MANAGEMENT and it is necessary to perform again the procedure ENABLING USER PASSWORD primary and service password Select PASSWORD ON OFF Press OK F1 Press the ON button to enable user passwords and return to the PASSWORD MANAGEMENT ...

Страница 12: ...is the only one that enables to enter the user password area and should therefore be known only by the owner of the store organization where the door is installed The service passwords 2 instead is used for employees or third parties that can use it to change the work programs of the door but cannot in any way change or disable both passwords To change the password 1 press the button A after selec...

Страница 13: ...ER SUPPLY FAILURE In case of power supply failure the door can be opened and closed manually If the door is equipped with an electric lock use the special key to unlock it If the automation is equipped with a battery depending on the programming of the electronic control unit the door may operate as follows a The door can be opened by activating any opening command motion radars buttons etc b The ...

Страница 14: ...f the program selector The door stops during the stroke and inverts the running direction The door detects an obstacle along its stroke Identify the obstacle and remove it Friction occurs along door stroke Properly set the door for this operation please contact the service centre The electronic control units beeps multiple times and door operation is irregular The defect depends on the number and ...

Страница 15: ...arned that the maintenance interval has expired when the message PROGRAMMED MAINTENANCE is shown on the display Each maintenance operation is recorded into the maintenance register The final user must limit himself to cleaning the glass surfaces the fixture profiles and if necessary the motion and presence sensors taking care to lock the door while performing these operations 8 DISPOSAL At the end...

Страница 16: ...MPANY QUALITY SYSTEM UNI EN ISO 9001 2000 Made in Italy by S p A Via Ilariuzzi 17 A S Pancrazio P se 43126 PARMA ITALIA Tel 39 05 21 67 52 Fax 39 05 21 67 52 22 infocom labelspa it www labelspa com LABEL service centre ...